Title of article
Simultaneous Determination of Isoniazid, Pyrazinamide and Rifampin in Human Plasma by High-performance Liquid Chromatography and UV Detection
Author/Authors
Dasht Bozorg, Behnam Department of Clinical Pharmacy - School of Pharmacy - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Goodarzi, Ali Department of Clinical Pharmacy - School of Pharmacy - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Fahimi, Fanak Department of Clinical Pharmacy - School of Pharmacy - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Tabarsi, Payam Chronic Respiratory Disease Research Center - National Research Institute of Tuberculosis and Lung Diseases (NRITLD) - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Shahsavari, Nahid Department of Clinical Pharmacy - School of Pharmacy - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Kobarfard, Farzad Phytochemistry Research Center - Department of Medicinal Chemistry - School of Pharmacy - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Dastan, Farzaneh Department of Clinical Pharmacy - School of Pharmacy - Shahid Beheshti University of Medical Sciences, Tehran, Iran
Pages
7
From page
1735
To page
1741
Abstract
Therapeutic Drug Monitoring (TDM) of first-line anti-tuberculosis (TB) drugs is a decisive
tool, allowing the clinician to successfully treat TB patients. The objective of the study was to
develop and optimize a simple, sensitive, and reliable high-performance liquid chromatography
(HPLC) method for the simultaneous determination of isoniazid (INH), pyrazinamide (PZA),
and rifampin (RIF) levels in human plasma. Nicotinamide was used as the internal standard
and the samples were prepared after protein precipitation using acetonitrile and zinc sulfate.
The separation was achieved using a C18 reversed-phase applying gradient elution. The mobile
phase was a combination of water–methanol solution with a ratio of 95:05 (v/v) at the initial
phase. All calibration curves had good linearity (r2 > 0.99) and the inter- and intra-day RSDs
were lower than 15%. The limit of detection with a signal-to-noise ratio (S/N) of 3:1 was 0.16,
0.5, and 0.33 μg mL–1 for INH, PZA, and RIF, respectively. The method presented here was
selective, sensitive, and reproducible, and could be used for therapeutic drug monitoring in the
patients who were under treatment with these drugs.
Keywords
Rifampin , Pyrazinamide , Isoniazid , HPLC-UV , Therapeutic drug monitoring , Anti-TB drugs