Numerical Research on the Impact of Axial Position of Endwall Suction Slot on Tip Leakage Flow
Author/Authors :
Zhang, B School of Power and Energy - Northwestern Polytechnical University - chaina , Liu, B. School of Power and Energy - Northwestern Polytechnical University - chaina , Rehman, A School of Power and Energy - Northwestern Polytechnical University - chaina , Sun, X School of Power and Energy - Northwestern Polytechnical University - chaina
Abstract :
In order to reduce the adverse effect of the tip leakage flow of cantilever stator on compressor performance, the
impact of the axial position of endwall streamwise suction slot on tip leakage flow was numerically studied.
The study on the overall performance of the compressor and the details of the flow field near the stator end
region with and without suction showed that all suction schemes could weaken the tip leakage flow intensity to
a certain extent, and the flow control effect was gradually enhanced with the increase of the suction flow rate.
In the case of small suction flow rate, for example, 0.5%, the short slot schemes can improve the overall
efficiency of the compressor by about 0.5%, which is more advantageous than the long slot scheme, and the
overall efficiency improvement of the latter is about 0.3%. The advantage of the long slot scheme in flow
control is reflected in the case of large suction flow rate, that is, 1.0%, which may improve the overall efficiency
of the compressor by about 0.96%. The axial position of suction slot has a significant influence on flow control
effect of the tip leakage flow. Compared with the downstream suction, which only modified the flow field by
reducing the blocking effect generated by tip flow vortex, the upstream suction could better control the tip
leakage flow by restraining the development of the initial stage of the leakage vortex. Besides, the endwall
suction scheme with a full chord length slot has the greatest impact on the passage vortex, its effect on
modifying the flow field near the end zone was determined by the combinatorial action of the enhancement of
the passage vortex and the attenuation of the leakage vortex
Keywords :
Cantilever Stator , Tip Leakage Flow , Endwall Suction , Suction Position , Passage Vortex , Blocking effect