Title of article :
Evaluation of an Integrated Cryogenic Natural Gas Process with the Aid of Advanced Exergy and Exergoeconomic Analyses
Author/Authors :
Ghorbani, Bahram Faculty of Engineering Modern Technologies - Amol University of Special Modern Technologies, Amol, Iran , Roshani, Hani Department of Mechanical Engineering - KNToosi University of technology, Tehran, Iran , Mehrpooya, Mehdi Department of Renewable Energies and Environment - Faculty of New Sciences & Technologies - University of Tehran, Tehran, Iran , Shirmohammadi, Reza Department of Renewable Energies and Environment - Faculty of New Sciences & Technologies - University of Tehran, Tehran, Iran , Razmjoo, Armin Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB) - Universitat Politècnica de Catalunya (UPC), 08028 Barcelona, Spain
Abstract :
Abstract: In this study, an integrated structure of the air separation unit, natural gas liquids
recovery equipped with nitrogen removal unit is developed. In this regard, advanced exergy
and exergoeconomic analyses are used to examine the irreversibility, possible improvements
and the cost of the inefficiencies of the process. The exergy analysis presents information on
the origin of the irreversibility as well as the amount of irreversibility of each component. The
results of advanced exergy analysis show that HX2, HX3, C1, C2, C3, AC1, AC3 equipment
have the highest amount of the irreversibility due to endogenous exergy destruction, whereas
the highest amount of the irreversibility in the rest of the equipment is because of exogenous
exergy destruction. Furthermore, avoidable exergy destruction of equipment is more than the
unavoidable exergy destruction in the C1, C2, and C3. This issue shows that with the
improvement of the efficiency of the equipment, it is feasible to reduce the irreversibility of
these systems. In addition, the results of advanced exergoeconomic analysis show that the
priority to improve the performance of the system should be devoted to the HX2, HX3, C1, C3,
AC1, AC3 equipment, respectively. The AC1 air cooler and the C3 compressor have the
highest amounts of investment cost of avoidable endogenous exergy destruction, respectively.
The heat exchanger HX3 and air cooler AC2 and AC3 have the lowest investment cost of
avoidable endogenous exergy destruction.
Keywords :
advanced exergoeconomic analysis , advanced exergy analysis , air separation unit , non-standard nitrogen separation , Natural gas liquids