Title of article :
High Power Laser and Photobiomodulation in Oral Surgery: Case Report
Author/Authors :
Gomes Lúcio de Araújo, Júlia Department of Dentistry I - Federal University of Maranhão - Av. Dos Portugueses - 1966 - Bacanga - 65080-805 - São Luis - MA, Brazil , Michele dos Santos Araújo, Erika Department of Operative Dentistry - School of Dentistry - University of São Paulo (USP) - São Paulo - SP, Brazil , Cristina Nogueira Rodrigues, Fernanda Department of Operative Dentistry - School of Dentistry - University of São Paulo (USP) - São Paulo - SP, Brazil , Aurélio Benini Paschoal, Marco PUC Minas University - R. Dom José Gaspar - 804 - Coração Eucarístico - 30535-000 - Belo Horizonte - MG, Brazil , Dias Neves Lago, Andréa Department of Dentistry I - Federal University of Maranhão - Av. Dos Portugueses - 1966 - Bacanga - 65080-805 - São Luis - MA, Brazil
Pages :
4
From page :
75
To page :
78
Abstract :
Introduction: The labial frenum is a fold of mucous membrane that attaches the lip and the cheek to the alveolar mucosa, the gingiva, and the underlying periosteum. In some cases, its presence can cause a midline diastema, periodontal diseases related to food impaction, or retention of biofilm, among others. In such cases, lip frenectomy is indicated as treatment, which can be performed with a scalpel (conventional method), an electric scalpel, or a surgical laser. Objective: To show a clinical case performed at Laser Extension Project in Dentistry, Federal University of Maranhao grounded in a literature review. Case Presentation: A laser frenectomy was performed on a female patient, aged 20, who had a diastema between the upper central incisors and an indication for frenum removal. The high-power diode laser is excellent for procedures in soft tissue because its wavelength is well absorbed by hemoglobin and other pigments; its use also allows a reduction in the amount of anesthetic and medicines used. The parameters used were 2 W, in a continuous mode, 808 nm infrared emission; with delivery of the beam through optical fiber 300 ƒÊM; energy of 120 J; 20 pps. Conclusion: the high power diode laser allowed a satisfactory result, the procedure was safe, the technique was a simple one and of reduced clinical time, as mentioned in the literature. It is worth noting that the technique is dependent on the skill of the professional performing it.
Keywords :
Diode lasers , Labial frenum , Periodontics
Journal title :
Journal of Lasers in Medical Sciences
Serial Year :
2019
Record number :
2501521
Link To Document :
بازگشت