Author/Authors :
Abootalebi Ghahnavieh, Alireza Emergency Medicine Research Center - Al-Zahra Research Institute - Isfahan University of Medical Sciences, Iran , Golshani, Keihan Emergency Medicine Research Center - Al-Zahra Research Institute - Isfahan University of Medical Sciences, Iran , Jafarpisheh, Mohammadsaleh Emergency Medicine Research Center - Al-Zahra Research Institute - Isfahan University of Medical Sciences, Iran , Moaiednia, Milad Emergency Medicine Research Center - Al-Zahra Research Institute - Isfahan University of Medical Sciences, Iran , Memarzade, Mohammad Ali Emergency Medicine Research Center - Al-Zahra Research Institute - Isfahan University of Medical Sciences, Iran , Maghami-Mehr, Asieh Department of Statistics - Payam Noor University, Shiraz, Iran
Abstract :
Background: Pulmonary thromboembolism (PTE) is a serious and lifethreatening condition. Diagnosis of PTE can be challenging in emergency
departments, as there is no absolutely reliable biomarker for the diagnosis of
PTE. Copeptin (COP) is a new biomarker, which may be valuable in the
diagnosis of PTE; however, its role has not been well studied. In this study, we
aimed to investigate the diagnostic value of COP in the diagnosis of PTE.
Materials and Methods: This study was carried out on 102 patients suspected
of PTE. The serum levels of D-dimer and COP were measured, and diagnosis of
PTE was confirmed by CT angiography. Next, the prognostic value of D-dimer
and COP was examined.
Results: The area under the curve (AUC) of D-dimer was 0.581 with a standard
error (SE) of 0.07 (P=0.34). Estimation of the validity of D-dimer showed that it
is a highly sensitive (100%), but poorly specific (15.8%) test. Evaluation of the
predictive value of this test showed that it has a positive predictive value of
20% and a negative predictive value of 100%. The AUC of COP was 0.423 with
SE of 0.1 (P=0.44). Measurement of the validity of COP test showed that it is a
poorly sensitive (50%) and specific (22.9%) test.
Conclusion: COP is a new cardiovascular biomarker. However, the present
findings did not confirm the prognostic value of this biomarker for the
diagnosis of PTE.
Keywords :
Copeptin , Pulmonary Embolism , D-dimer , Validity