Title of article :
Catalytic Oxidation of Carbon Monoxide from Vented Gas Space Heaters Using Alumina foam Supported CuMnOx Nanocatalyst
Author/Authors :
Abbasi, Alireza Shiraz University of Medical Sciences - School of Health - Department of Environmental Health Engineering , Yosefinejad, Saeed Shiraz University of Medical Science - Department of Occupational Health Engineering , Bahrami, Shima Shiraz University of Medical Sciences - School of Health - Department of Environmental Health Engineering , Hoseini, Mohamad Shiraz University of Medical Sciences - School of Health - Department of Environmental Health Engineering
Abstract :
Background: Carbon monoxide (CO) is an odorless, tasteless,
colorless, and nonirritating poisonous gas, recognized as the
silent killer for the 21st century. It is produced during partial
combustion of carbon-containing compounds. Improper
ventilation and flue installation of vented gas space heaters cause
carbon monoxide gas to penetrate the building, leading to many
deaths annually. The catalytic oxidation of CO has received great
attention due to its applications in different fields. In this study,
alumina foam coated by CuMnOx catalyst was used to remove
CO from the vented gas space heaters.
Methods: This is a full-scale experimental study on the outflow
from vented gas space heaters. Alumina foam supported hopcalite
(CuMnOx) catalyst was synthesized using a co-precipitation
method for CO oxidation from the vented gas space heaters.
The XRD and SEM were used to characterize the synthesized
catalyst. The concentration of CO was measured by IMR 1500
combustion gas analyzer.
Results: The particle size of the catalyst was in the range of 200-
600 nm. XRD showed different crystallizations, and the crystal
size was in the range of 20-120 nm. There was no significant CO
removal in the case of using uncoated alumina foam. Results
showed CuMnOx catalyst significantly increased the CO removal.
The removal efficiencies were 83% and 89% in heating powers of
2300 and 3200 kcal/hr, respectively. The average CO conversation
rate was approximately 60.45 μg/gr.min.
Conclusion: CuMnOx coated on alumina has a significant effect
on CO removal from the vented gas space heaters. The catalyst
and outlet gas temperature were the most important factors
affecting CO removal.
Keywords :
Carbon monoxide , Hopcalite , Air pollution , Indoor
Journal title :
Journal of Health Sciences and Surveillance System