Title of article :
Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up
Author/Authors :
Martìn Patiño, Juan Upper Extremity Unit Orthopedics and Traumatology Department - Hospital Militar Central - Argentina , Felix Rullan Corna, Alejandro Upper Extremity Unit Orthopedics and Traumatology Department - Hospital Militar Central - Argentina , Emilio Michelini, Alejandro Upper Extremity Unit Orthopedics and Traumatology Department - Hospital Militar Central - Argentina , Abdon, Ignacio Upper Extremity Unit Orthopedics and Traumatology Department - Hospital Militar Central - Argentina , Denise Hochbaum, Sandra Upper Extremity Unit Orthopedics and Traumatology Department - Hospital Militar Central - Argentina , Zicovich Wilson, Fernando Upper Extremity Unit Orthopedics and Traumatology Department - Hospital Militar Central - Argentina
Pages :
7
From page :
105
To page :
111
Abstract :
Background: The aim of this study was to evaluate functional outcome and complications with a long term follow up (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured locking plates. Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed, as well as functional evaluation using the rating scale shoulder of the University of California (UCLA), the Constant scale, score of disability of the arm, shoulder and hand (DASH) and visual analog scale (VAS). Postoperative complications, implants removal rates and new x-rays were analized. Results: The mean postoperative follow-up was 41.5 (24; 69. SD 13.4) months. Mean shoulder anterior elevation was 168.5º (120; 180. SD 22.9). The average value obtained for abduction was 175.2° (150; 180. SD 27.8), as to internal and external rotations, these were not affected. DASH 1.27% (0%; 25%. SD 4.3), UCLA 33.6 points (20; 35. SD 3.5), Constant 90.5 points (50; 100. SD 11.2) and VAS was 0 in 34 patients (83%). Complications: mild residual pain (3), hypoesthesia of the infraclavicular area (2), and rupture (1) and loosening (1) of the implant. hardware removal due to intolerance (2 cases) and new osteosynthesis due to acute implant rupture (1 case). Conclusion: Our experience after a mean follow-up of 41.5 months with precontoured locking plates for the treatment of displaced mid-shaft clavicle fractures has shown good functional results, with low complication and reoperation rate. Level of evidence: IV Keywords
Keywords :
Clavicle , Complications , Fractures , Hardware removal , Osteosynthesis , Outcomes , Plates
Journal title :
The Archives of Bone and Joint Surgery
Serial Year :
2019
Record number :
2515104
Link To Document :
بازگشت