Farahmandfar, Fatemeh Nuclear Medicine Research Center - Mashhad University of Medical Sciences, Iran , Shakeri, Sara Nuclear Medicine Research Center - Mashhad University of Medical Sciences, Iran , Masoudi, Toktam Nuclear Medicine Research Center - Mashhad University of Medical Sciences, Iran , Zarehparvar Moghadam, Soroush Nuclear Medicine Research Center - Mashhad University of Medical Sciences, Iran , Sadeghi, Ramin Nuclear Medicine Research Center - Mashhad University of Medical Sciences, Iran
Pages
4
From page
30
To page
33
Abstract
Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilationperfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with
history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed
multiple mismatched defects throughout both lungs. SPECT images showed that only one of the defects was real, the others
were caused by patient’s elevated right arm. Our case showed a V/Q pitfall with emphasis on importance of SPECT imaging
in V/Q scintigraphy.
Keywords
Ventilation-perfusion scan , SPECT , 99mTc-MAA , 99mTc- DTPA