Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis
Author/Authors :
Hafezeqoran, Ali Department of Prosthodontics - Dental faculty - Tabriz University of medical sciences, Tabriz , Koodaryan, Roodabeh Department of Prosthodontics - Dental faculty - Tabriz University of medical sciences, Tabriz , Hemmati, Yasser Department of Prosthodontics - Dental faculty - Tabriz University of medical sciences, Tabriz , Akbarzadeh, Ayshin Department of Prosthodontics - Dental faculty - Tabriz University of medical sciences, Tabriz
Pages :
5
From page :
221
To page :
225
Abstract :
Background. Designing a high strength all-ceramic fixed partial denture with favorable esthetics can be challenging for clinicians; this study aimed to evaluate the effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prostheses. Methods. Two groups of twenty -3unit monolithic zirconia (Sirona inCoris TZI, Sirona Dental Systems GmbH) bridges, extending from the mandibular first premolar to the first molar with different connector sizes (9 mm2 and 12 mm2), were divided into two subgroups with different connector designs (round and sharp). The specimens were subjected to the three-point bending test to obtain the fracture-bearing load. The results were reported using descriptive statistics (mean ± standard deviation). Mann-Whitney U test was used to compare the fracture load in two types of designs for each connector size and two connector size types for each connector design. The significance level was considered at P<0.05. Results. The minimum failure load was related to the group with a -9mm2 connector size and a sharp embrasure design (133.89±1054.4 N), and the highest mean value belonged to the group with -12mm2 connector size and rounded embrasure design (167.09±1599.8 N). Mann-Whitney U test indicated a significant difference between the mean failure load of the rounded and sharp embrasure designs in the -9mm2 connector size (P=0.007). However, the difference was insignificant in the -12mm2 connector size (P=0.075). Conclusion. Sharp embrasure design is not recommended for high-stress areas with restricted occlusogingival height. A -9mm2 connector size for -3unit monolithic zirconia FDP, which is recommended by the manufacturer, should be used more cautiously.
Keywords :
Dental ceramics , Fixed partial denture , Load-bearing , Monolithic zirconia
Journal title :
Journal of Dental Research, Dental Clinics, Dental Prospects
Serial Year :
2020
Record number :
2519921
Link To Document :
بازگشت