Title of article :
The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
Author/Authors :
Sarebani, Maghsoud Department of Medical Physics - School of Medicine - Iran University of Medical Sciences, Tehran, Iran , Shiran, Mohammad Bagher Department of Medical Physics - School of Medicine - Iran University of Medical Sciences, Tehran, Iran , Bitarafan-Rajabi, Ahmad Cardiovascular Intervention Research Center - Rajaie Cardiovascular Medical and Research Center - Iran University of Medical Sciences, Tehran, Iran , Rastgou, Feridoon Rajaie Cardiovascular Medical and Research Center - Iran University of Medical Sciences, Tehran, Iran , Ojaghi Haghighi, Zahra Department of Echocardiography, Rajaei Cardiovascular - Medical and Research Center - Iran University of Medical Science, Tehran, Iran , Abbasian Ardakani, Ali Department of Medical Physics - School of Medicine - Iran University of Medical Sciences, Tehran, Iran
Pages :
7
From page :
57
To page :
63
Abstract :
Background: Cardiac echocardiography and cardiac ECG-gated single-photon emission computed tomography (SPECT) are the most common modalities for left ventricle (LV) volumes and function assessment. The temporal resolution of SPECT images is limited and an ECG provides better temporal resolution. This study investigates the impact of frame numbers on images in terms of qualitative and quantitative assessments. Methods: In this study, 5 patients underwent echocardiography and cardiac ECG-gated SPECT imaging, and 5 standard views of the LV were recorded to determine LV walls boundaries and volumes. Also, 2 original images with 8 frames and 16 frames per cardiac cycle were recorded simultaneously in a single gantry orbit. Using the data extracted from the LV model, 8 extra new frames were created with interpolation between existing frames of the original 8-frame image. Three series of images (8 and 16 original and 16 interpolated) were reconstructed separately. LV volumes and ejection fraction (EF) were calculated using Quantitative Gated SPECT (QGS) software. Results: Compared to the original 8-frame gating, original 16-frame gated images resulted in larger end-diastole volume (EDV) (mean ± SD: 68.6 ± 27.11 mL vs 66.2±25.41 mL, p<0.001), smaller end-systole volume (ESV) (mean ± SD: 24.6±8.7 mL vs 26±7.3 mL, p<0.001), and higher EF (64% vs 60.2%, p<0.001). The results for the interpolated series were also different from the original images (closer to the original 16-frame series rather than 8-frame). Conclusion: Changing the frame number from 8 to 16 in cardiac ECG-gated SPECT images caused a significant change in LV volumes and EF. Frame interpolation with sophisticated algorithms can be used to improve the temporal resolution of SPECT images.
Keywords :
SPECT , Echocardiography , Interpolation , End-diastole volume (EDV) , End-systole volume (ESV) , Ejection fraction (EF)
Journal title :
Medical Journal of the Islamic Republic of Iran
Serial Year :
2020
Record number :
2526030
Link To Document :
بازگشت