Title of article
Rating Reduction and Optimized DC-Link Voltage of the HPQC in Co-Phase Traction Power System
Author/Authors
Habibolahzadeh, M. Department of Electrical Engineering - Iran University of Science and Technology (IUST), Tehran , Jalilian, A. Department of Electrical Engineering - Iran University of Science and Technology (IUST), Tehran
Pages
9
From page
1
To page
9
Abstract
Electric traction trains are huge non-linear single-phase loads influencing adversely on power quality parameters on the grid side. Hybrid power quality conditioner (HPQC) has been utilized to compensate current unbalance, harmonics, and low power factor in the co-phase traction system simultaneously. By incrementing the traction load, the rating of the HPQC increases and may constraints its application. In this paper, a C-type filter is designed to compensate for some part of the load reactive power while the HPQC compensates the remaining part of the load reactive power. Hence, the capacity of the HPQC is reduced in full compensation (FC) mode compared to the conventional configuration. The satisfactory performance of the HPQC is associated with its DC-link operating voltage. Therefore, the Genetic algorithm (G.A) is adopted to optimize the DC-link voltage performance. Simulation verifications are performed to illustrate the usefulness of the proposed configuration. The simulation results show an 18.86% reduction in the rating of the HPQC with optimized DC-link voltage.
Keywords
HPQC , C-Type Filter , Co-Phase , Power Quality
Journal title
Iranian Journal of Electrical and Electronic Engineering(IJEEE)
Serial Year
2021
Record number
2526976