Title of article :
Consistency Conditions for Cone-Beam CT Data Acquired with a Straight-Line Source Trajectory
Author/Authors :
LEVINE, Margo S University of Chicago - Department of Radiology, USA , SIDKY, Emil Y University of Chicago - Department of Radiology, USA , PAN, Xiaochuan University of Chicago - Department of Radiology, USA
From page :
56
To page :
61
Abstract :
A consistency condition is developed for computed tomography (CT) projection data acquired from a straight-line X-ray source trajectory. The condition states that integrals of normalized projection data along detector lines parallel to the X-ray path must be equal. The projection data is required to be untruncated only along the detector lines parallel to the X-ray path, a less restrictive requirement compared to Fourier conditions that necessitate completely untruncated data. The condition is implemented numerically on simple image functions, a discretization error bound is estimated, and detection of motion inconsistencies is demon- strated. The results show that the consistency condition may be used to quantitatively compare the quality of projection data sets obtained from different scans of the same image object.
Keywords :
data redundancy , John’s equation , consistency conditions
Journal title :
Tsinghua Science and Technology
Journal title :
Tsinghua Science and Technology
Record number :
2535237