Title of article :
The Rimmed Prolene Mesh in Ventral Hernioplasty: A Novel Configuration for a Better Pro-Peritoneal Application
Author/Authors :
ABDEL-SAMAD, HISHAM MUSTAFA Cairo University - Faculty of Medicine - Department of Surgery, Egypt , EZZELDEEN, MAHMOUD M. Cairo University - Faculty of Medicine - Department of Surgery, Egypt , OMAR, AHMAD F. Cairo University - Faculty of Medicine - Department of Surgery, Egypt , EL-MAADAWY, MOHAMED Cairo University - Faculty of Medicine - Department of Surgery, Egypt
From page :
619
To page :
626
Abstract :
Introduction: The development of abdominal wall defects is remarkable in surgical practice. Therefore, trials are never stopping to improve the methods of repair of such defects. Tension-free repairs using prosthetic materials are highly recommended, as long as a durable reconstruction is desirable. Debate always exists as regards the best prosthetic material; however polypropylene is the most commonly used one. Polypropylene mesh implants are available in many designs, configurations, thicknesses of weaves strands, and sizes of pores. The Aim of the Work: Is to revive the valuable sublay positioning of the prolene mesh by presenting a novel configuration of the mesh rimmed prolene mesh, which is supposed to facilitate its application in the pro-peritoneal space, with comparison of the results to those of the commonly used onlay technique. Patients and Methods: Eighty nine patients with ventral hernia were enrolled into the study, during the period between January 2004 and October 2006. Seventy five cases were females, and 14 were males. They were randomly allocated between two groups of management, (A) (B). Group (A) was formed of 44 patients with a mean age of 40 years (30- 57). In this group, pro-peritoneal (sublay) rimmed prolene mesh (RPM) ventral hernioplasty was done. Group (B) included 45 patients with a mean age of 42 years (32-54). This represented the cotrol group in which the common procedure of pro-parietal (onlay) flat mesh hernioplasty was applied. The method of preparation of the rimmed mesh and the technique of its application are described. Intra-operative and postoperative findings were recorded for both groups, and the results were compared. Results: The presence of the rim configuration of the mesh had the following benefits in the pro-peritoneal application: It allowed fixation of the mesh to the edge of the fascial defect and obviated the need to close the defect over the mesh as in Rives Stoppa technique. Consequently, this insured a more tension-free repair. The 3-5 mm-height rim made it easier and faster to take the bites in the mesh during its fixation to the facial defect. The height of the rim also obviated the need to dip the needle down into the mesh that overlies the peritoneum, thus avoiding any event of a suture entangling a bowel loop, thus adding an element of safety. Otherwise, the comparison of results of the two groups of cases revealed shorter operative time and hospital stay in group A compared to B, being 92 (60-140) minutes 1.86 (1-3) days for group A 120 (75-180) minutes 2.97 (4-9) days for group B. The overall rate of complications was also less in group (A), particularly the incidence of seroma. No recurrence was encountered in either group till the end of October 2006. Conclusion: The rimmed prolene mesh (RPM) is a novel configuration for a simple, rapid, efficient and safe properitoneal application in treatment of ventral hernia. Further trials of application of the RPM are recommended to evaluate its effectiveness. A ready-made RPM may then be available, allowing its use at a wide scale.
Keywords :
Ventral hernia , Hernioplasty , Prolene mesh , Pro , peritoneal , Rim , Tension free.
Journal title :
The Medical Journal of Cairo University
Journal title :
The Medical Journal of Cairo University
Record number :
2538162
Link To Document :
بازگشت