Radiological performance of hot water layer system in open pool type reactor
Author/Authors
Abdelhady, Amr Atomic Energy Authority - Nuclear Research Center - Reactors Department, Egypt
From page
159
To page
162
Abstract
The paper presents the calculated dose rate carried out by using MicroShield code to show the importance of hot water layer system (HWL) in 22 MW open pool type reactor from the radiation protection safety point of view. The paper presents the dose rate profiles over the pool surface in normal and abnormal operations of HWL system. The results show that, in case of losing the hot water layer effect, the radiation dose rate profiles over the pool surface will increase from values lower than the worker permissible dose limits to values very higher than the permissible dose limits.
Keywords
Radiation dose calculation , Radiological hazard , Open pool research reactor , Radioprotection
Journal title
Alexandria Engineering Journal
Journal title
Alexandria Engineering Journal
Record number
2540164
Link To Document