Title of article :
Design, Fabrication and Parametric Study of Bulk Current Injection Probe and Its Calibration Fixture
Author/Authors :
Mashriki, Issa M. High Institute for Applied Science and Technology - Syria - Damascus , Razavi, S.M.J. Faculty of Electrical & Computer Engineering - Malek Ashter University of Technology - Iran - Tehran , Armaki, S.H.M. Faculty of Electrical & Computer Engineering - Malek Ashter University of Technology - Iran - Tehran
Abstract :
Abstract- In this paper, the fabrication of a bulk current injection (BCI)
probe using two different ferrite materials and a wideband roundedshield calibration fixture or jig used to calibrate BCI probe are
presented. Some optimization ideas are also investigated to increase
their performance. The effect of change in various parameters such as
slot distance, probe’s shield to probe’s core spacing and the inner
surface of probe’s shield on the probe high frequency performance and
insertion loss (IL) have been studied. Results show that increasing the
slot distance improves the high frequency response of the probe and
increasing the probe’s shield to probe’s core spacing would affect
negatively on measured IL and decreasing the inner surface of probe’s
shield improves the probe working bandwidth.
Index Terms-
Keywords :
Bulk current injection (BCI) , calibration fixture (CF or JIG) , electromagnetic Compatibility (EMC) , optimization , parametric study
Journal title :