Title of article :
Development of Low-Cost Current Controlled Stimulator for Paraplegics
Author/Authors :
Masdar, Aizan Universiti Tun Hussein Onn Malaysia - Department of Mechatronic and Robotic Engineering, Malaysia , Masdar, Aizan Universiti Tun Hussein Onn Malaysia - Faculty of Electrical and Electronic Engineering, Malaysia , Ibrahim, B. S. K. K. Universiti Tun Hussein Onn Malaysia - Department of Mechatronic and Robotic Engineering, Malaysia , Ibrahim, B. S. K. K. Universiti Tun Hussein Onn Malaysia - Faculty of Electrical and Electronic Engineering, Malaysia , Abdul Jamil, M. Mahadi Universiti Tun Hussein Onn Malaysia - Faculty of Electrical and Electronic Engineering - Department of Electronic Engineering, Malaysia , Abdul Jamil, M. Mahadi Universiti Tun Hussein Onn Malaysia - Modeling andSimulation Research Laboratory, Faculty of Electrical and Electronic Engineering, Malaysia
From page :
40
To page :
47
Abstract :
A spinal cord injury (SCI) has a severe impact on human life in general as well as on the physical status and condition. The use of electrical signals to restore the function of paralyzed muscles is called functional electrical stimulation (FES). FES is a promising way to restore mobility to SCI by applying low-level electrical current to the paralyzed muscles so as to enhance that person’s ability to function and live independently. However, due to the limited number of commercially available FES assisted exerciser systems and their rather high cost, the conventional devices are unaffordable for most peoples. It is also inconvenient because of wired based system that creates a limitation in performing exercise. Thus, this project is concerned with the development of low-cost current controlled stimulator mainly for the paraplegic subjects. The developed device is based on a microcontroller, wireless based system using Zigbee module, voltage-to-current converter circuit and should produce proper monopolar and bipolar current pulses, pulse trains, arbitrary current waveforms, and a trigger output for FES applications. This device has been developed as in the new technique of the stimulator development with low cost and one of the contributing factors in Rehabilitation Engineering for patients with SCI.
Keywords :
Functional electrical stimulation (FES) , voltage current converter , wireless , low cost
Journal title :
International Journal of Integrated Engineering
Journal title :
International Journal of Integrated Engineering
Record number :
2565386
Link To Document :
بازگشت