Title of article :
Passive neutron area monitor with CR39
Author/Authors :
Vega-Carrillo, H.R. Universidad Autonoma de Zacatecas - Unidad Académica de Estudios Nucleares, Mexico , Barquero, R. Hospital Universitario Rio Hortega - Departamento de Radiología, Spain , Mercado, G.A. Universidad Autónoma de Zacatecas - Unidad Academica de Matematicas, Mexico
Abstract :
Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless; in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with CR39 track detector has been calculated with the MCNPX code. To increase the detection efficiency a 10B converter was included. The response was calculated using 47 monoenergetic neutron sources. Results: A passive neutron area monitor using a CR39 with 10B converter was designed where fluence and H*(10) responses were calculated. Conclusion: The shape of the responses is similar to responses reported for neutron monitors with active detectors.
Keywords :
Neutron dosimetry , passive detector , CR , 39 , Monte Carlo , response.
Journal title :
International Journal of Radiation Research
Journal title :
International Journal of Radiation Research