Title of article :
EXERGY BASED OPTIMIZATION OF A BIOMASS an‎d SOLAR FUELLED CCHP HYBRID SEAWATER DESALINATION PLANT
Author/Authors :
Ghasemi, Amir Faculty of Environment - University of Tehran, Tehran , Hashemian, Nasim Faculty of Environment - University of Tehran, Tehran , Noorpoor, Alireza Faculty of Environment - University of Tehran, Tehran , Heidarnejad, Parisa Faculty of Environment - University of Tehran, Tehran
Pages :
10
From page :
1034
To page :
1043
Abstract :
Integrated energy systems utilizing renewable sources are a sustainable and environmentally substitution for conventional fossil fired energy systems. A CCHP hybrid seawater desalination plant with two inputs such as biomass and solar energy and four useful outputs such as cooling, heating, power and distillated water is presented and investigated in this paper. The proposed system includes evacuated tube solar collectors, biomass burner, organic rankine cycle (ORC), absorption chiller, heater and multi effect desalination system (MED). The results showed that the proposed system is able to produce 802.5KW as power, 10391 KW as heating, 5658 KW as cooling and 9.328 kg/s distillated water. Energy efficiency of the system is 61 %, the exergy efficiency is 7 % and the main sources of exergy destructions are biomass burner, evacuated tube solar collectors and vapor generator. Exergy optimization is carried out in order to find the optimum point of system.
Keywords :
Exergy , CCHP , Desalination , Optimization , Solar Energy , Biomass
Journal title :
Journal of Thermal Engineering
Serial Year :
2017
Full Text URL :
Record number :
2571685
Link To Document :
بازگشت