• Title of article

    Detection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography

  • Author/Authors

    Farajzadeh, Mir Ali Department of Analytical Chemistry - Faculty of Chemistry - University of Tabriz, Tabriz, Iran - Engineering Faculty - Near East University - 99138 Nicosia - North Cyprus - Mersin 10, Turkey , Pezhhanfar, Sakha Department of Analytical Chemistry - Faculty of Chemistry - University of Tabriz, Tabriz, Iran , Mohebbi, Ali Department of Analytical Chemistry - Faculty of Chemistry - University of Tabriz, Tabriz, Iran , Afshar Mogaddam, Mohammad Reza Food and Drug Safety Research Center - Tabriz University of Medical Sciences, Tabriz, Iran

  • Pages
    18
  • From page
    303
  • To page
    320
  • Abstract
    Migration of chemicals from plastic containers into drinks and liquids is supposed to be a hazardous phenomenon resulting in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid-liquid microextraction is applied for the extraction and preconcentration of the migrated compounds prior to their detection and determination by gas chromatography equipped with mass spectrometry or flame ionization detector. The method is based on forming droplets of a water-immiscible organic solvent (extractant) into an aqueous phase using a disperser solvent. As a result, there would be a large contact area between the extractant and aqueous phase containing the analytes which boosts mass transfer. After centrifuging, the extractant is sedimented at the bottom of the aqueous phase and an aliquot of it is removed and injected into the separation system. Various experimental conditions influencing the extraction efficiency were optimized. Under the optimum conditions, the extraction recoveries were ranged from 52-63%. Also, the enrichment factors for the target compounds were calculated to be in the range of 2600-3150. The linear ranges were achieved in the range of 0.61-1000 μg l-1. The relative standard deviations were ≤ 7.2% for intra- (n = 6) and inter-day (n = 4) precisions at a concentration of 20 μg l-1 of each analyte. The limits of detection were in the range of 0.18-0.38 μg l-1. Eventually, the applicability of the proposed method for appraising the migrated compounds from plastic containers including butylated hydroxy anisole, butylated hydroxy toluene, bisphenol A, dibutyl phthalate, diethyl phthalate, di-isobutyl phthalate, and p-xylene was evaluated by analyzing them in different drinks and liquids stored in the plastic bottles.
  • Keywords
    Plastic bottles , Phthalate esters , Antioxidants , Endocrine disruptors , Dispersive liquid-liquid microextraction , Gas chromatography
  • Journal title
    Analytical and Bioanalytical Chemistry Research
  • Serial Year
    2020
  • Record number

    2574869