Title of article :
Determining the Critical Intensity for Crack Initiation in Concrete Arch Dams by Endurance Time Method
Author/Authors :
Mashayekhi, Mohammadreza Assistant Professor - K.N. Toosi University of Technology - Tehran, Iran , Mostafaei, Hasan Department of Civil Engineering - Isfahan University of Technology - Isfahan, Iran
Abstract :
This study aims at determining the critical seismic intensity at which cracks are expected to
develop in a concrete arch dam. This intensity is referred to as crack initiation intensity. The
crack initiation intensity measure implies that earthquakes with the intensity measure higher
than this value are expected to induce cracks in the arch dam. This quantity is an indicator for
seismic evaluation of arch dams. Determining this parameter using conventional time history
analyses requires multiple trials and errors applying several up and down scaling of a suite of
ground motions which can be very time consuming. As an alternative method, endurance time
method is well suited for this kind of study. In the endurance time method, structures are
subjected to predefined intensifying acceleration time histories and all intensity measures are
continuously covered in a single time history analysis. The continuous coverage of intensity
measures in the endurance time method provides a tool to conveniently determine the transition
points such as crack initiation in a single time history analysis. In this regard, a framework is
proposed and then applied to Morrow point dam, a doubly curved arch dam, as a case study.
Results are obtained by using three different endurance time excitation series; ‘kn’, ‘kd’, and
‘lc’. The aim of using three endurance time series was to compare their differences in dynamic
analysis of arch dams. Observations indicate the acceptable compatibility of different series of
endurance time excitation. In order to investigate the accuracy of the results obtained by the
endurance time method, the dynamic analysis of the arch dam subjected to ten ground motions scaled by the calculated crack initiation intensity measure is performed. It is shown that the
proposed method can be conveniently applied for determining the crack initiation intensity.
Keywords :
seismic response assessment , arch dam , endurance time analysis , tensile stress , crack initiation , performance parameter
Journal title :
Journal of Numerical Methods in Civil Engineering