Title of article
THERMODYNAMIC PERFORMANCE ANALYSIS OF DEDICATED MECHANICALLY SUBCOOLED VAPOUR COMPRESSION REFRIGERATION SYSTEM
Author/Authors
Agarwal, S. Department of Mechanical Engineering - Delhi Technological University, Delhi, India , Arora, A. Department of Mechanical Engineering - Delhi Technological University, Delhi, India , Arora, B. B. Department of Mechanical Engineering - Delhi Technological University, Delhi, India
Pages
15
From page
222
To page
236
Abstract
In this work, the thermodynamic analysis of dedicated mechanically subcooled vapour compression refrigeration system is presented. A software based computer program in EES has been formulated for computation of the performance results. The effect of varation of degree of subcooling (5-30°C), evaporator temperature (-20 to 10°C) and condenser temperature (30-50°C) has been investigated for energetic and exergetic performance of the system. The analysis of the system has been carried out using zero ODP and very low GWP (1 to 4) refrigerants viz.HFO-R1234ze and R1234yf to compare the performance of HFC-R134a. The results depicts that the COP and exergetic efficiency of dedicated subcooled VCR cycle are better than that of simple VCR cycle. Refrigerant R1234ze performs better than R1234yf and comparable to R134a.
Keywords
VCR , Subcooling , COP , R1234ze , R1234yf , Exergetic Efficiency , Dedicated , R134a
Journal title
Journal of Thermal Engineering
Serial Year
2019
Record number
2583405