Title of article :
Safe and effective use of conscious sedation for defibrillation threshold testing during ICD implantation
Author/Authors :
Al Fagih, Ahmed Prince Sultan Cardiac Center - Cardiology Department, Saudi Arabia , Al Shurafa, Hitham Prince Sultan Cardiac Center - Cardiology Department, Saudi Arabia , Al Ghamdi, Saleh Prince Sultan Cardiac Center - Cardiology Department, Saudi Arabia , Dagriri, Khaled Prince Sultan Cardiac Center - Cardiology Department, Saudi Arabia , Al Khadra, Ayman Prince Sultan Cardiac Center - Cardiology Department, Saudi Arabia
From page :
209
To page :
213
Abstract :
Background: Over a period of years general anesthesia has been a standard anesthetic technique for defibrillation threshold (DFT) testing at the time of implant. DFT testing without general anesthesia cover has gained limited acceptance. Use of local anesthesia combined with deep sedation for DFT testing might facilitate and simplify these procedures by reducing the procedural time, staff time, avoiding inefficient service in organizing anesthetic cover; thereby improving patient compliance. Objective: The objective of this study was to evaluate feasibility, safety and efficacy of conscious sedation for DFT testing during Implantable cardioverter defibrillators (ICD) implantation.Method: Data of 87 non-selected patients who achieved adequate sedation with titrated doses of midazolam and pethidine were analyzed retrospectively. These medications were administered by a circulating nurse under the supervision of the implanting physicians. All hemodynamic measures, treatment and complications were monitored and recorded throughout the procedure. Results: A retrospective analysis of data from 87 patients who underwent ICD implantation and DFT testing under conscious sedation at our center was reported. The mean dose of midazolam and pethidine administered was 4.9± 1.8 and 47.7 ±20 mg, respectively. During the period of conscious sedation, no patient depicted episode of sustained apnea. No major complication or mortality was reported. Conclusion: Use of conscious sedation as an alternative to the use of general anesthesia for DFT testing during ICD implantation is found to be feasible, safe and effective, with an added advantage of reduced procedural time and improved patient compliance.
Keywords :
Conscious sedation , Defibrillation threshold testing , Implantable cardioverter defibrillators
Journal title :
journal of the saudi heart association
Journal title :
journal of the saudi heart association
Record number :
2585213
Link To Document :
بازگشت