Title of article
FLOW PERFORMANCE COMPARISON ALONG THE CENTERLINE IN STRAIGHT and S-SHAPED DIFFUSER
Author/Authors
Sharma, Amit Departmental of Mechanical Engineering - Govt. Engineering College of Bikaner, India , Gupta, Arun Department of Mechanical Engineering - Amity University Haryana, India , Singh, Hardial Department of Mechanical Engineering - Amity University Haryana, India
Pages
14
From page
58
To page
71
Abstract
In this paper of the S-shaped diffuser with area ratio (AR) 1.5, an experimental investigation was conducted to analyze the effect of the change in curvature of a straight-wall diffuser. During this study, a Straight diffuser was changed in to a curved diffuser at different angles as their same upper and lower limbs (60/60, 90/90). Profile equations of diffusers were generated with the help of MATLAB/Simulink v2017a software. In this work centerline length is constant for all three profiles, Centerline length that’s utilized in the sector of circle and radius of curvature is calculated. S-shaped diffuser had a different unique angle with square inlet and a rectangular outlet. S-shaped diffuser CPR and CTL results compared with a straight walled diffuser with the different inlet velocity and Reynolds Number. These outcomes from this research obtained the coefficient of static pressure gain and coefficient of total
pressure loss for the three profile of the diffuser (Straight, 60/60, and 90/90 S-Shaped Diffuser).
Keywords
Coefficient of Static Pressure Recovery , Coefficient of Total Pressure Loss , S-Shaped Diffuser
Journal title
Journal of Thermal Engineering
Serial Year
2020
Record number
2585844
Link To Document