Title of article :
Successful Thrombolysis of Occluded Inferior Vena Cava Filter with IVC Syndrome
Author/Authors :
Srinivas, BC Sri Jayadeva Institute of Cardiovascular Sciences and Research - Department of Cardiology, India , Singh, Ajit Pal Sri Jayadeva Institute of Cardiovascular Sciences and Research - Department of Cardiology, India
From page :
119
To page :
122
Abstract :
Thrombosis of Inferior Vena Cava (IVC) following filter insertion can occur in up to 30% of the cases. The optimal management of such cases is unknown. We describe a simple and less expensive method of achieving successful recanalization of the IVC in a 40 year old hypertensive man who developed recurrent pulmonary embolism after his orthopedic treatment. An IVC filter was inserted, which developed extensive thrombosis of the whole IVC and venous system of the lower limbs. Catheter directed thrombolysis using a multiple side-hole multipurpose catheter and balloon angioplasty was carried out in order to “crush and lyse” the IVC thrombi.
Keywords :
Inferior Vena Cava , IVC Filter Thrombosis , Catheter Directed Thrombolysis , Balloon Angioplasty
Journal title :
Journal of Cardiovascular and Thoracic Research (JCVTR)
Journal title :
Journal of Cardiovascular and Thoracic Research (JCVTR)
Record number :
2589502
Link To Document :
بازگشت