Title of article :
P-Wave Dispersion and Atrial Electromechanical Delay in Patients with Preeclampsia
Author/Authors :
İnci, Sinan Aksaray State Hospital - Department of Cardiology, Turkey , Nar, Gökay Aksaray State Hospital - Department of Cardiology, Turkey , Aksan, Gökhan Gazi State Hospital - Department of Cardiology, Turkey , Sipahioğlu, Haydar Aksaray State Hospital - Department of Obstetrics, Turkey , Soylu, Korhan Ondokuz Mayis University - Faculty of Medicine - Department of Cardiology, Turkey , Dogan, Ali Erciyes University - Faculty of Medicine - Department of Cardiology, Turkey
From page :
515
To page :
521
Abstract :
Objectives: To investigate the duration of atrial electromechanical delay (EMD) and left atrial mechanical function in patients with preeclampsia. Materials and Methods: This study included 26 pregnant women with preeclampsia and 24 age-matched pregnant women without preeclampsia (control group). Atrial electromechanical coupling (PA) and intra-atrial and interatrial EMD were measured using tissue Doppler echocardiography. P-wave dispersion (PWD) was measured via 12-lead electrocardiography. All data were analyzed using SPSS v.15.0 for Windows (SPSS, Inc., Chicago, Ill., USA). Differences in continuous variables between groups were examined using a nonparametric Mann-Whitney U test. Correlation analysis was performed using Spearman’s coefficient of correlation. Categorical values were compared using a χ² test. Results: PA lateral and PA septal durations were significantly longer in the preeclampsia group than in the control group [74.6 ± 8.1 vs. 62.3 ± 5.3 ms (p 0.001) and 59.7 ± 5.3 vs. 56.2 ± 4.9 ms (p = 0.005), respectively]. The duration of interatrial EMD and intra-atrial EMD in the preeclampsia group was significantly longer than in the control group [25.4 ± 4.6 vs. 13.2 ± 3.9 ms (p 0.001) and 10.5 ± 1.9 vs. 7.1 ± 1.2 ms (p 0.001), respectively]. PWD was significantly higher in patients with preeclampsia (43.1 ± 9.1 ms) than in the controls (37.6 ± 7.9 ms; p = 0.008). There was a significant correlation between PWD and interatrial EMD and intra-atrial EMD [r = 0.46 (p 0.001) and r = 0.39 (p 0.001), respectively]. Conclusion: The duration of atrial EMD and PWD was prolonged in patients with preeclampsia.
Keywords :
Atrial electromechanical delay · Intra , atrial conduction time · Interatrial conduction time · Preeclampsia · Tissue Doppler imaging
Journal title :
Medical Principles and Practice
Journal title :
Medical Principles and Practice
Record number :
2590986
Link To Document :
بازگشت