Title of article :
An Improved Method of Automated Noise Measurement System in CT Images
Author/Authors :
Anam ، Choirul Department of Physics - Faculty of Sciences and Mathematics - Diponegoro University , Arif ، Idam Department of Physics - Faculty of Mathematics and Natural Sciences - Bandung Institute of Technology , Haryanto ، Freddy Department of Physics - Faculty of Mathematics and Natural Sciences - Bandung Institute of Technology , Lestari ، Fauzia P Department of Physics - Faculty of Mathematics and Natural Sciences - Bandung Institute of Technology , Widita ، Rena Department of Physics - Faculty of Mathematics and Natural Sciences - Bandung Institute of Technology , Budi ، Wahyu S Department of Physics - Faculty of Sciences and Mathematics - Diponegoro University , Sutanto ، Heri Department of Physics - Faculty of Sciences and Mathematics - Diponegoro University , Adi ، Kusworo Department of Physics - Faculty of Sciences and Mathematics - Diponegoro University , Fujibuchi ، Toshioh Department of Health Sciences - Faculty of Medical Sciences - Kyushu University , Dougherty ، Geoff Department of Applied Physics and Medical Imaging - California State University Channel Islands
Abstract :
Background: It is necessary to have an automated noise measurement system working accurately to optimize dose in computerized tomography (CT) examinations. Objective: This study aims to develop an algorithm to automate noise measure ment that can be implemented in CT images of all body regions. Materials and Methods: In this retrospective study, our automated noise measurement method consists of three steps as follows: the first is segmenting the image of the patient. The second is developing a standard deviation (SD) map by cal culating the SD value for each pixel with a sliding window operation. The third step is estimating the noise as the smallest SD from the SD map. The proposed method was applied to the images of a homogenous phantom and a full body adult anthropo morphic phantom, and retrospectively applied to 27 abdominal images of patients. Results: For a homogeneous phantom, the noises calculated using our proposed and previous algorithms have a linear correlation with R^2 = 0.997. It is found that the noise magnitude closely follows the magnitude of the water equivalent diameter (Dw) in all body regions. The proposed algorithm is able to distinguish the noise magni tude due to variations in tube currents and different noise suppression techniques such as strong, standard, mild, and weak ones in a reconstructed image using the AIDR 3D algorithm. Conclusion: An automated noise calculation has been proposed and successfully implemented in all body regions. It is not only accurate and easy to implement but also not influenced by the subjectivity of user.
Keywords :
Ionizing radiation , X , rays , Computed Tomography , Image Quality , Automated Noise Calculation , Algorithms , Image Processing , Computer , Assisted
Journal title :
Journal of Biomedical Physics and Engineering
Journal title :
Journal of Biomedical Physics and Engineering