Abstract :
Peri-implant fractures distal to an antegrade femoral nail are uncommon injuries, with no current consensus on the best treatment modality. We are presenting three cases of periimplant fractures distal to an antegrade femoral nail. All patients sustained an initial traumatic injury, which was
managed with an antegrade femoral nail fixation. They
subsequently suffer a second injury which causes periimplant fracture. Our first two patients were managed with
removing the intramedullary nail followed by Less Invasive
Stabilization System (LISS) plate fixation. In our third case,
the intramedullary nail was left in-situ, and the fracture was
fixed with a polyaxial locking plate We discuss their injury
pattern, investigations and surgical management. Polyaxial
locking plates show great promise in this setting as they
allow fixation of the fracture whilst maintaining the existing nail to protect the entire femur from further injury.