• Title of article

    A Modified Technique of Fixation for Proximal Femoral Valgus Osteotomy in Abnormal Bone: A Report of Two Cases

  • Author/Authors

    S, Logheswaren Department of Orthopaedics - Universiti Sains Malaysia - Kubang Kerian - Malaysia , AR, Sulaiman Department of Orthopaedics - Universiti Sains Malaysia - Kubang Kerian - Malaysia , I, Munajat Department of Orthopaedics - Universiti Sains Malaysia - Kubang Kerian - Malaysia

  • Pages
    3
  • From page
    82
  • To page
    84
  • Abstract
    The ideal size of intramedullary device to fix corrective osteotomy of proximal femur in abnormal bone in children and small patients may not be easily available. We report the successful use of Rush rod in combination with multiple Kirschner wires to fix the corrective osteotomy of coxa vara and shepherd crook deformity in two patients with osteogenesis imperfecta and fibrous dysplasia. The unio‎n was achieved on time, neck shaft angle and rotation were maintained.
  • Keywords
    valgus osteotomy , modified technique , abnormal bone
  • Journal title
    Malaysian Orthopaedic Journal
  • Serial Year
    2017
  • Record number

    2603418