Author/Authors :
Miyamoto, Seiko Department of Clinical Laboratory - National Hospital Organization Wakayama Hospital, Wada Mihama-cho, Wakayama, Japan , Minakata, Yoshiaki Department of Clinical Laboratory - National Hospital Organization Wakayama Hospital, Wada Mihama-cho, Wakayama, Japan , Azuma, Yuichiro Department of Clinical Laboratory - National Hospital Organization Wakayama Hospital, Wada Mihama-cho, Wakayama, Japan , Kawabe, Kazumi Department of Clinical Laboratory - National Hospital Organization Wakayama Hospital, Wada Mihama-cho, Wakayama, Japan , Ono, Hideya Department of Clinical Laboratory - National Hospital Organization Wakayama Hospital, Wada Mihama-cho, Wakayama, Japan , Yanagimoto, Ryuta Department of Clinical Laboratory - National Hospital Organization Wakayama Hospital, Wada Mihama-cho, Wakayama, Japan , Suruda, Tadatoshi Department of Clinical Laboratory - National Hospital Organization Wakayama Hospital, Wada Mihama-cho, Wakayama, Japan
Abstract :
Background. Objective evaluation of the physical activity (PA) in patients with chronic obstructive pulmonary disease (COPD) is
important. We validated a triaxial accelerometer, Active Style Pro HJA-750C® (HJA), and evaluated the necessary conditions for
obtaining reproducible data. Methods. The PA measured by HJA was compared with that measured by two already validated
accelerometers in 11 patients with COPD (age: 76.6 ± 6.9, FEV1% predicted: 57.6 ± 18.6). Then, the influence of weather and
holidays on the PA and the required number of days to obtain repeatability were examined in 21 patients with COPD (age: 73.0 ±
8.0, FEV1% predicted: 58.7 ± 19.0). Results. +e PA values measured by HJA and those by DynaPort Move Monitor® (DMM) or
Actimarker® (AM) were significantly correlated at all intensities (p = 0.024 at ≥4.0 METs by DMM and p < 0.0001 at the rest)
except at ≥4.0 METs by AM, though the values measured by HJA were higher than those by AM which was reported to underestimate PA. The durations of PA on rainy days were significantly shorter than those on nonrainy days, but those on holidays
were not different from those on weekdays. The values of ICC for 3, 4, or 5 days were higher than 0.8 at all intensities. The PA
measured by HJA was correlated with the dyspnea scale FVC and age and tended to correlate with FEV1. Conclusions. The HJA
was validated for evaluating the PA in patients with COPD. This trial is registered with UMIN000016363.