Title of article :
Positive Pneumocystis jirovecii Sputum PCR Results with Negative Bronchoscopic PCR Results in Suspected Pneumocystis Pneumonia
Author/Authors :
Pennington, Kelly Division of Pulmonary and Critical Care Medicine - Department of Medicine - Mayo Clinic, Rochester, USA , Wilson, John Division of Infectious Diseases - Department of Medicine - Mayo Clinic, Rochester, USA , Limper, Andrew H. Division of Pulmonary and Critical Care Medicine - Department of Medicine - Mayo Clinic, Rochester, USA , Escalante, Patricio Division of Pulmonary and Critical Care Medicine - Department of Medicine - Mayo Clinic, Rochester, USA
Pages :
6
From page :
1
To page :
6
Abstract :
Introduction. *e diagnostic standard for Pneumocystis jirovecii pneumonia (PCP) is direct microscopic identification; however, in recent years, polymerase chain reaction (PCR) from bronchoalveolar lavage (BAL) samples to detect Pneumocystis nucleic acids has proven to be more sensitive and specific. Sputum samples have been presumed inferior to bronchoscopic samples secondary to variability and adequacy of sample collection. We observed several cases of positive sputum PCP-PCR results with negative PCPPCR BAL results. *e aim of the current study was to further characterize the clinical setting and outcomes in patients with positive sputum PCP-PCR samples and negative BAL PCP-PCR samples. Methods. We identified all patients who underwent P. jirovecii-PCR testing at Mayo Clinic between 2011 and 2016. Patients with a positive sputum and negative BAL sample collected within a 14-day time frame were identified and underwent further chart review for demographics, immunocompromised state, and clinical outcome. Results. From 2011 to 2016, 4431 respiratory samples from 3021 unique patients were tested for the presence of P. jirovecii by PCR. Fifty-five samples (1.2% of all samples collected) belonging to 24 unique patients (0.79% of patients tested) were identified as having a positive and negative sample collected within 14 days. Of these 24 patients, 10 (46%) patients had a positive sputum or tracheal secretion sample with negative BAL or bronchial washings. Out of these 10 patients, 8 were immunocompromised and 9 underwent treatment for PCP with 6 patients improving. Conclusion. Our results suggest that discordant P. jirovecii-PCR testing results from sputum and bronchoscopic specimens are an infrequent occurrence. Patients with positive P. jirovecii-PCR sputum/tracheal secretion samples and negative bronchoscopic samples appear to be clinically infected and respond to PCP treatment. Sputum P. jirovecii-PCR testing may be a viable alternative to invasive testing
Keywords :
Pneumocystis jirovecii , Sputum PCR , Bronchoscopic , Pneumocystis Pneumonia
Journal title :
Canadian Respiratory Journal
Serial Year :
2018
Full Text URL :
Record number :
2605729
Link To Document :
بازگشت