Author/Authors :
Wu, Yajun Department of Civil Engineering - Shanghai University, Shanghai, Chin , Song, Binjie Department of Civil Engineering - Shanghai University, Shanghai, Chin , Lu, Yitian Department of Civil Engineering - Shanghai University, Shanghai, Chin , Deng, Qingyang Shanghai Urban Operation (Group) Co. - Huangpu District, Shanghai, China , Chen, Guang Shanghai Chengtou Wastewater Treatment Co. Ltd. - Shanghai, Chin
Abstract :
At present, there is a lack of necessary technical parameters for sludge vacuum reinforcement. To explore the effects of the drain board type on sludge vacuum reinforcement, the Fenton reagent was used to pretreat the landfill sludge in a sludge landfill area in Shanghai, and then, vacuum preloading contrast tests of different prefabricated vertical drainage types were carried out. During the test, the discharge and settlement of sludge were recorded. After the test, the moisture content, shear strength, and appearance of PVD were measured and analysed. The main conclusions are as follows: (1) the optimum ratio of H2O2 and Fe2+ is 2 for the landfill sludge; (2) the total displacement and accumulated settlement of the test group with integral prefabricated vertical drainage are 1.7 times and 1.2 times those of the separate prefabricated vertical drainage, respectively; (3) the type of prefabricated vertical drainage has no effect on the distribution of water content and shear strength; and (4) when the sludge is vacuum strengthened, the integral prefabricated vertical drainage should be preferred.