Author/Authors :
Nishida, Norihiro Department of Orthopedic Surgery - Yamaguchi University Graduate School of Medicine - Minami-Kogushi -Yamaguchi, Japan , Ohgi, Junji Faculty of Engineering - Yamaguchi University - Tokiwadai - Yamaguchi, Japan , Jiang, Fei Faculty of Engineering - Yamaguchi University - Tokiwadai - Yamaguchi, Japan , Ito, Saki Faculty of Engineering - Yamaguchi University - Tokiwadai - Yamaguchi, Japan , Imajo, Yasuaki Department of Orthopedic Surgery - Yamaguchi University Graduate School of Medicine - Minami-Kogushi -Yamaguchi, Japan , Suzuki, Hidenori Department of Orthopedic Surgery - Yamaguchi University Graduate School of Medicine - Minami-Kogushi -Yamaguchi, Japan , Funaba, Masahiro Department of Orthopedic Surgery - Yamaguchi University Graduate School of Medicine - Minami-Kogushi -Yamaguchi, Japan , Nakashima, Daisuke Department of Orthopedic Surgery - Yamaguchi University Graduate School of Medicine - Minami-Kogushi -Yamaguchi, Japan , Sakai, Takashi Department of Orthopedic Surgery - Yamaguchi University Graduate School of Medicine - Minami-Kogushi -Yamaguchi, Japan , Chen, Xian Department of Orthopedic Surgery - Yamaguchi University Graduate School of Medicine - Minami-Kogushi -Yamaguchi, Japan
Abstract :
Spinal compression fractures commonly occur at the thoracolumbar junction. We have previously constructed a 3-dimensional
whole-spine model from medical images by using the finite element method (FEM) and then used this model to develop a
compression fracture model. However, these models lacked the rib cage. No previous study has used whole-spine models
including the rib cage constructed from medical images to analyze compression fractures. Therefore, in this study, we added the
rib cage to whole-spine models. We constructed the models, including a normal spine model without the rib cage, a whole-spine
model with the rib cage, and whole-spine models with compression fractures, using FEM analysis. Then, we simulated a person
falling on the buttocks to perform stress analysis on the models and to examine to what extent the rib cage affects the analysis of
compression fractures. The results showed that the intensity of strain and the vertebral body with minimum principle strain
differed between the spine model including the rib cage and that excluding the rib cage. The strain on the spine model excluding
the rib cage had approximately twice the intensity of the strain on the spine model including the rib cage. Therefore, the rib cage
contributed to the stability of the thoracic spine, thus preventing deformation of the upper thoracic spine. However, the presence
of the rib cage increased the strain around the site of compression fracture, thus increasing the possibilities of a refracture and
fractures of adjacent vertebral bodies. Our study suggests that the analysis using spine models including the rib cage should be
considered in future investigations of disorders of the spine and internal fracture fixation. The development of improved models
may contribute to the improvement of prognosis and treatment of individual patients with disorders of the spine.
Keywords :
Whole-Spine , Rib , FEM , Element , 3D