Title of article :
Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants
Author/Authors :
Ihde, Stefan Dental Implants Faculty - International Implant Foundation, Munich, Germany , Pałka, ukasz Reg-Med Dental Clinic - Rzeszowska, Żary, Poland , Janeczek, Maciej Department of Biostructure and Animal Physiology - Wroclaw University of Environmental and Life Sciences, Kożuchowska, Wroclaw, Poland , Kosior, Piotr Department of Conservative Dentistry and Pedodontics - Wroclaw Medical University, Krakowska, Wroclaw, Poland , Kiryk, Jan Private Dental Clinic Maciej Kozłowski, Spokojna, Oleśnica, Poland , Dobrzyński, Maciej Department of Conservative Dentistry and Pedodontics - Wroclaw Medical University, Krakowska, Wroclaw, Poland
Pages :
5
From page :
1
To page :
5
Abstract :
The aim of this article was to present the clinical application of a new, smooth surfaced one-piece bicortical screw implant with immediate loading protocol. An 18-year-old, healthy male patient with a history of total dislocation and replantation of teeth 11 and 21 in early childhood was admitted to the clinic. Teeth 11 and 21 were extracted, and two long one-piece implants were inserted at extraction sockets in one surgical session under local anesthesia. Temporary composite crowns were placed in the patient on the same day. After 3 months, the single-phase two-layer impression was made and the composite crowns were replaced with metal-ceramic crowns. After 12 months, satisfactory aesthetic and functional results were obtained.
Keywords :
Bite Reconstruction , Aesthetic Zone , Bicortical Screw Implants
Journal title :
Case Reports in Dentistry
Serial Year :
2018
Full Text URL :
Record number :
2616349
Link To Document :
بازگشت