Title of article :
Baseline serum globulin as a predictor of the recurrence of lone atrial fibrillation after radiofrequency catheter ablation
Author/Authors :
Zhou, Qing Department of Thoracic and Cardiovascular Surgery - the Affiliated Drum Tower Hospital of Nanjing University Medical School - Nanjing - China , Cao, Hailong Department of Thoracic and Cardiovascular Surgery - the Affiliated Drum Tower Hospital of Nanjing University Medical School - Nanjing - China , Xu, Zhenjun Department of Thoracic and Cardiovascular Surgery - the Affiliated Drum Tower Hospital of Nanjing University Medical School - Nanjing - China , Lan, Rongfang Department of Cardiology - the Affiliated Drum Tower Hospital of Nanjing University Medical School - Nanjing - China , Chen, Xin Department of Cardiology - the Affiliated Drum Tower Hospital of Nanjing University Medical School - Nanjing - China , Wang, Dongjin Department of Thoracic and Cardiovascular Surgery - the Affiliated Drum Tower Hospital of Nanjing University Medical School - Nanjing - China , Xu2, Wei Department of Thoracic and Cardiovascular Surgery - the Affiliated Drum Tower Hospital of Nanjing University Medical School - Nanjing - China
Pages :
5
From page :
381
To page :
385
Abstract :
Objective: Inflammation and autoimmune responses play an important role in recurrence of atrial fibrillation (AF). Serum globulin levels are a commonly used clinical index that represents inflammation and autoimmune response. This study aimed to determine the relationship between baseline serum globulin levels and the risk of recurrence after ablation in lone AF patients. Methods: We enrolled 348 lone AF patients undergoing radiofrequency catheter ablation for the first time for whom complete follow-up data were available. Pre-ablation peripheral venous blood samples were obtained for measurement of serum globulin levels. Results: During the follow-up period of 22 months (range, 6–62), AF recurred in 129 patients (37.1%). Recurrence was associated with a low level of pre-ablation serum globulins. Multiple Cox proportional hazard regression analysis showed that persistent AF, AF duration, left atrial diameter, no amiodarone after ablation, and the serum globulin level in particular were independent predictors of AF recurrence. According to receiver operating characteristic curve analysis, the best diagnostic cut-off serum globulin level was 25.4 g/L, which showed 74.4% sensitivity, 71.3% specificity, and 73.3% accuracy. Conclusion: The baseline low serum globulin level is associated with AF recurrence after first-time ablation in lone AF patients. Therefore, it may be used as a predictor of AF recurrence in these patients. Keywords:
Keywords :
lone atrial fibrillation , globulin , radiofrequency catheter ablation , serum , recurrence
Journal title :
The Anatolian Journal of Cardiology: Andolu Kardiyoloji Dergisi
Serial Year :
2017
Full Text URL :
Record number :
2616938
Link To Document :
بازگشت