Title of article :
Study of Binding Kinetics and Specificity of 99mTc-SSS-Complex and 99mTc-HMPAO to Blood Cells
Author/Authors :
Auletta, S Department of Medical-Surgical Sciences and of Translational Medicine - Faculty of Medicine and Psychology - “Sapienza” University of Rome, Italy , Iodice, V Department of Medical-Surgical Sciences and of Translational Medicine - Faculty of Medicine and Psychology - “Sapienza” University of Rome, Italy , Galli, F Department of Medical-Surgical Sciences and of Translational Medicine - Faculty of Medicine and Psychology - “Sapienza” University of Rome, Italy , Lepareur, N Nuclear Medicine Department - Centre Eugene Marquis - Universite Europeen de Bretagne - Rennes Cedex, France , Signore, A Department of Medical-Surgical Sciences and of Translational Medicine - Faculty of Medicine and Psychology - “Sapienza” University of Rome, Italy
Pages :
6
From page :
1
To page :
6
Abstract :
Nuclear medicine ofiers several techniques and procedures to image infection, but radiolabelled autologous white blood cells (WBCs) are still the gold standard. These cells are usually labelled with 111In or 99mTc bound to a hydrophobic chelating agent that allows these isotopes to pass through the plasma membrane and enter in the cytoplasm. The most common compound in Europe is HMPAO that eficiently chelates 99mTc. However, up to 20–40% of the complex is released from the cells in the rst few hours. The aim of this study was to radiolabel a new compound, (S3CPh)2 (S2CPh)-complex (SSS-complex) with 99mTc and compare its binding kinetics and specicity for WBC with HMPAO. The SSS-complex was labelled with 99mTc and analysed by iTLC and RPHPLC. In vitro quality controls included a stability assay in serum and saline. Results showed a labelling eficiency of 95 ± 1.2% and 98 ± 1.4% for 99mTc-SSS-complex and 99mTc-HMPAO, respectively (p = ns). 99mTc-SSS-complex was stable in serum and in saline up to 24 h (94 ± 0.1%). Cell labelling experiments showed a higher incorporation of 99mTc-SSS-complex than 99mTc-HMPAO by granulocytes (62.6 ± 17.8% vs 40.5 ± 15%, p = 0.05), lymphocytes (59.9 ± 22.2% vs 29.4 ± 13.5%; p = 0.03), and platelets (44.4 ± 24% vs 20.5 ± 10.7%; p = ns), but the release of radiopharmaceutical from granulocytes at 1 h was lower for HMPAO than for SSScomplex (10.3 ± 1.9% vs 21.3 ± 1.8%; p = 0.001). In conclusion, 99mTc-SSS-complex, although showing high labelling eficiency, radiochemical purity, and stability, is not a valid alternative to 99mTc-HMPAO, for example, in vivo white blood cells labelling because of high lymphocyte and platelet uptake and rapid washout from granulocytes.
Keywords :
99mTc-SSS , 99mTc-HMPAO , Blood , HMPAO
Journal title :
Contrast Media and Molecular Imaging
Serial Year :
2018
Full Text URL :
Record number :
2617629
Link To Document :
بازگشت