Title of article :
Noninferiority of 99mTc-Ethylenedicysteine-Glucosamine as an Alternative Analogue to 18F-Fluorodeoxyglucose in the Detection and Staging of Non-Small Cell Lung Cancer
Author/Authors :
Dai, Dong Tianjin Medical University Cancer Institute and Hospital - Tianjin, China , David Rollo, F Point Biotechnology - Centennial, USA , Bryant, Jerry Point Biotechnology - Centennial, USA , Edmund Kim, E University of Texas MD Anderson Cancer Center - Houston, USA
Abstract :
99mTc-ethylenedicysteine-glucosamine (99mTc-EC-G) was developed as a potential alternative to 18F-FDG for cancer
imaging. A Phase 2 study was conducted to compare 18F-FDG PET/CT and 99mTc-EC-G SPECT/CT in the detection and staging
of patients with non-small cell lung cancer (NSCLC). Tis study was aimed to demonstrate that 99mTc-EC-G SPECT/CT was not
inferior to 18F-FDG PET/CT in patients with confrmed NSCLC. Methods. Seventeen patients with biopsy proven NSCLC were
imaged with 99mTc-EC-G and 18F-FDG to detect and stage their cancers. Imaging with PET/CT began 45–60 minutes after injection
of 18F-FDG. Imaging with 99mTc-EC-G began at two hours after injection (for 5 patients) or three hours (for 12 patients). SPECT/CT
imaging devices from the three major vendors of SPECT/CT systems were used at 6 participating study sites. The image sets were
blinded to all clinical information and interpreted by independent PET and SPECT expert readers at a central independent core
laboratory. Results. 100% concordance between 99mTc-EC-G and 18F-FDG for primary lesion detection, lesion location and size,
and confidence that the biopsied lesion was malignant. There was 70% agreement between 99mTc-EC-G and 18F-FDG for metastatic
lesion detection, location and size, and confidence that the suspicious lesions were malignant. Conclusions. Evaluation of primary
and suspicious metastatic lesions detected by 99mTc-EC-G and 18F-FDG on 17 patients resulted in excellent agreement for detection
of primary and metastatic lesions. The study results indicated that 99mTc-EC-G SPECT/CT has the potential to be a clinically viable
alternative to 18F-FDG PET/CT and 99mTc-EC-G is not inferior to 18F-FDG PET/CT.
Keywords :
99mTc , Glucosamine , PET/CT
Journal title :
Contrast Media and Molecular Imaging