Title of article :
The accuracy of paediatric weight estimation during simulated emergencies: The effects of patient position, patient cooperation, and human errors
Author/Authors :
Wells, Mike Division of Emergency Medicine - Faculty of Health Sciences - University of the Witwatersrand - Parktown - Johannesburg, South Africa , Goldstein, Lara Nicole Division of Emergency Medicine - Faculty of Health Sciences - University of the Witwatersrand - Johannesburg - Gauteng, South Africa , Bentley, Alison Division of Emergency Medicine - Faculty of Health Sciences - University of the Witwatersrand - Johannesburg - Gauteng, South Africa
Pages :
8
From page :
43
To page :
50
Abstract :
The effect of patient position and patient cooperation on the accuracy of emergency weight estimation systems has not been evaluated previously. The objective of this study was to evaluate weight estimation accuracy of the Broselow tape, the PAWPER XL tape, the Mercy method, and a custom-designed mobile phone App in a variety of realistic simulated paediatric emergencies. Methods This was a prospective study in which 32 emergency medicine volunteers participated in eight simulations of common paediatric emergency conditions, using children models. The participants used each of the four methods to estimate the children’s weight. The accuracy of and time taken for the weight estimations were evaluated for each method. A regression analysis determined the effects of patient position and cooperation on weight estimation accuracy. Evaluation of subgroups of best-performers and worst-performers among the participants provided information on the effects of human user-error on weight estimation accuracy. Results The Broselow tape, Mercy method, App and the PAWPER XL tape achieved percentages of weight estimation within 10% of actual weight in 47.7, 57.3, 68.1, and 73.0% of estimations, respectively. Patient position and cooperation strongly impacted the accuracy of the Broselow tape, had a minimal effect on the Mercy method and the App, and had no effect on the PAWPER XL tape. The best performing participants achieved very high accuracy with all methods except the Broselow tape. Discussion The Mercy method, the App, and the PAWPER XL tape achieved exceptionally high accuracy even in uncooperative and sub-optimally positioned children when used by the best-performing participants. Human error, from inexperience and inadequate training, had the most significant impact on accuracy. The Mercy method was the most subject to human error, and the PAWPER XL tape, the least. Adequate training in using weight estimation systems is essential for paediatric patient safety.
Keywords :
Mercy method , PAWPER tape , Broselow tape , Paediatric weight estimation , Resuscitation , Body weight
Journal title :
African Journal of Emergency Medicine
Serial Year :
2018
Full Text URL :
Record number :
2618788
Link To Document :
بازگشت