• Title of article

    An Unnoticed Broken Sheathed Metallic Stylet in an Endotracheal Tube: A case report

  • Author/Authors

    Sharma, Pradeep K National Trauma Centre - Khoula Hospital - Department of Anesthesia ICU, Oman , Khan, Rashid M National Trauma Centre - Khoula Hospital - Department of Anesthesia ICU, Oman , Kaul, Naresh National Trauma Centre - Khoula Hospital - Department of Anesthesia ICU, Oman

  • Pages
    3
  • From page
    126
  • To page
    128
  • Abstract
    We report a 58-years old patient, who underwent surgery for a fracture to the neck of the femur. Tracheal intubation was performed with the aid of a stylet; however, 15 minutes later, it was brought to the notice of the attending anesthesiologist that a broken piece of stylet had been left inside the lumen of the endotracheal tube. Prior to this, there was no evidence of a foreign body in the endotracheal tube or tracheobronchial tree. The broken piece of stylet was successfully retrieved with the help of a Kocher’s forceps
  • Keywords
    Broken stylet , Endotracheal tube obstruction , Foreign body , Case report , Oman