In-Vitro Comparison of the Effect of XP-Endo Shaper and One-Shape Rotary Files on the Incidence of Root Dentin Cracks
Author/Authors
Delvarani, A Department of Endodontics- Member Ship of Dental Material Research Center - Faculty of Dentistry - Tehran Medical Sciences - Islamic Azad University - Tehran, Iran , Moshary, AA Department of Endodontics- Member Ship of Dental Material Research Center - Faculty of Dentistry - Tehran Medical Sciences - Islamic Azad University - Tehran, Iran , Ghasemian Yadegari, M No affiliation , Bitaraf, T Dental Implant Research Center - Dental Faculty - Tehran Medical Sciences - Islamic Azad University - Tehran, Iran
Pages
6
From page
31
To page
36
Abstract
Root canal preparation with systems with the least chance of
dentin cracking can increase the success of endodontic treatment. This study aimed to
compare the One-Shape and XP-endo Shaper rotary files in the dentin crack incidence
in the mesiobuccal canals of mandibular first molars.
Materials and Methods: In this experimental study, 60 eligible extracted mandibular
first molars were randomly divided into three groups. The roots were prepared to #30
and 4% taper in the XP-endo Shaper group and #25 and 6% taper in the One-Shape
group. The control samples were left intact. All groups were sectioned at 2, 4, and
6mm from the apex and examined under a stereomicroscope at 20× magnification.
The incidence, location, and type of cracks were analyzed using chi-square test.
Result: There were no cracks in the controls. The crack percentage was 23.33%
(n=14) and 11.66% (n=7) in the One-Shape and XP-endo Shaper groups, respectively,
with a significant difference with crack-fee samples. There was no significant difference
between One-Shape and XP-endo Shaper systems in the three sections (P>0.05).
In the 2mm section, cracks were observed in six sections (10%) with One-Shape and
four sections (20%) with XP-endo Shaper. In the 4mm section, cracks were observed
in one section (5%) with One-Shape and five sections (25%) with XP-endo Shaper. In
the 6mm section, cracks were observed in seven sections (35%) with One-Shape and
one section (5%) with XP-endo Shaper.
Conclusion: The One-Shape and XP-endo Shaper systems were similar in crack incidence
in the mesiobuccal canal of mandibular first molars.