Title of article :
Validity of a Serological Diagnostic Kit for SARS-CoV-2 Available in Iran
Author/Authors :
Shamsollahi, Hamid Reza Department of Environmental Health Engineering - Tehran University of Medical Sciences - Tehran - Iran , Amini, Mostafa Deputy of Treatment Affairs - Tehran University of Medical Sciences - Tehran - Iran , Alizadeh, Shaban Department of Hematology - Tehran University of Medical Sciences - Tehran - Iran , Nedjat, Saharnaz Department of Epidemiology and Biostatistics - Tehran University of Medical Sciences - Tehran - Iran , Akbari-Sari, Ali Department of Health Management and Economics - Tehran University of Medical Sciences - Tehran - Iran , Rezaei, Mehdi Department of Orthopedics - Tehran University of Medical Sciences - Tehran - Iran , Allameh, Farshad Department of Gastroenterology - Imam Khomeini Hospital - Tehran University of Medical Sciences - Tehran - Iran , Fotouhi, Akbar Department of Epidemiology and Biostatistics - Tehran University of Medical Sciences - Tehran - Iran , Yunesian, Masud Department of Environmental Health Engineering - Tehran University of Medical Sciences - Tehran - Iran
Abstract :
Background: The Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) epidemic broke out in December 2019 and is now characterized as a pandemic. Effective control of this infectious disease requires access to diagnostic techniques, for both case finding and epidemic size estimation. The molecular technique is routinely used worldwide. Although it is the “standard” case detection and management method, it has its own shortcomings. Thus, some easy-to-use rapid serological tests have been developed.
Methods: One hundred and fourteen positive RT-PCR-diagnosed patients were tested by VivaDiag Kit, a brand of rapid serological kits available in hospitals affiliated to Tehran University of Medical Sciences (TUMS), Tehran, Iran. Frozen serum specimens taken from healthy people in summer and fall 2019 were also tested as negative controls.
Results: Test sensitivity was 47.9% (95% confidence interval [CI]: 38.8-56.9) for IgM and 47.0% (95% CI: 38.0–56.0) for IgG. There was no difference between IgG and IgM seropositivity except in one case. Specificity was calculated as 99.0% (95% CI: 96.4–99.9) for IgM and of 100.0% (95% CI: 0.98.2–100.0) for IgG. Sensitivity was higher in men and older participants.
Conclusion: This test can be used for epidemiological investigations, especially for the estimation of the level of infection in the community, after it is properly corrected for sensitivity and specificity. The low sensitivity could be attributed to the technical limitations of the kit or low levels of antibodies after infection. The different sensitivity in age and sex groups supports the hypothesis that different people show different immune responses to this virus.
Keywords:
Keywords :
Coronavirus , COVID-19 , SARS-CoV-2 , Sensitivity , Serologic tests
Journal title :
Archives of Iranian Medicine