Title of article :
Surface discoloration of composite resins: Effects of staining and bleaching
Author/Authors :
Poggio, Claudio University of Pavia - Department of Operative Dentistry, Italy , Beltrami, Riccardo University of Pavia - Departments of Operative Dentistry, Italy , Scribante, Andrea University of Pavia - Departments of Operative Dentistry, Italy , Colombo, Marco University of Pavia - Departments of Operative Dentistry, Italy , Chiesa, Marco University of Pavia - Departments of Operative Dentistry, Italy
From page :
567
To page :
573
Abstract :
Background: The purpose of this in vitro study was to evaluate surface discoloration of three microhybrid composite resins (Esthet•X HD, Clearfil AP-X, Gradia Direct) and five nanohybrid composite resins (Ceram•X, GC Kalore, G-aenial, Grandio, GrandioSO), after staining and bleaching procedures. Materials and Methods: The composite resins were polymerized with a curing light (Celalux II, Voco, Cuxhaven, Germany) into 160 silicon molds (6,4 mm in diameter and 2 mm in thickness) to obtain identical specimens. Twenty samples for each composite resin were prepared. The specimens were polished using an automated polishing machine with the sequence of 600-, 800-, 1000-grit abrasive paper under water irrigation. The specimens were immersed in tea and distilled water: the specimens were dipped for 20 min, once a day (every 24 h), for 14 days into the drinks. The specimens were then bleached with carbamide peroxide at 17% (Perfect Bleach-Voco). The color of specimens was measured with a spectrophotometer according to the CIE L*a*b* system after light-polymerization of composite resin specimens, after 7 days, after 14 days, and after bleaching. The color difference h index (DEab*) between each measurement was calculated. Statistical analysis was made using analysis of variance (ANOVA). Results: All specimens showed a significant increase in staining with a similar trend and no significant differences between microhybrid and nanohybrid composite resins. After whitening procedures, materials tested showed both significant and unsignifi cant differences of the h index. Conclusions: Microhybrid and nanohybrid composite resins had similar in vitro surface discoloration in tea. After bleaching, discoloration was removed from some composite resins tested.
Keywords :
Bleaching , composite resin , surface discoloration
Journal title :
DRJ Dental Research Journal
Journal title :
DRJ Dental Research Journal
Record number :
2636635
Link To Document :
بازگشت