Title of article :
The Study of Electrical Description for Non-Thermal Plasma Needle System
Author/Authors :
abbas, ibrahim karim anbar university - college of science - department of physics, Iraq , hussein, mohammed ubaid anbar university - college of medicine - department of physiology and medical physics, Iraq , murbat, hamid h. university of baghdad - college of science for women - department of physics, Iraq
Abstract :
In this research, a non-thermal plasma system was designed and a non-thermal plasma needle was manufactured for argon gas operating at normal atmospheric pressure. The electrical description of this system studied by using two different values of voltages (4.9,8) kV. Where the results showed the small amount of electrical current consumed by the system of plasma needle up to several microns of amps, and the value of the electrical current increase with the increasing gas flow, as well as the results, showed that happen a breakdown voltage at (8) kV when gas flow (4 l/min) causing a slight decrease in the electrical current value.
Keywords :
Non thermal plasma , plasma needle , Electrical description
Journal title :
Iraqi Journal Of Science
Journal title :