• Title of article

    Thermal performance of different working fluids in a dual diameter circular heat pipe

  • Author/Authors

    Peyghambarzadeh, S.M. islamic azad university - Department of Chemical Engineering, ايران , Shahpouri, S. islamic azad university - Department of Chemical Engineering, ايران , Aslanzadeh, N. islamic azad university - Department of Chemical Engineering, ايران , Rahimnejad, M. babol noshirvani university of technology - Department of Chemical Engineering, بابل, ايران

  • From page
    855
  • To page
    861
  • Abstract
    In this paper, heat transfer performance of a 40 cm-length circular heat pipe with screen mesh wick is experimentally investigated. This heat pipe is made of copper with two diameters; larger in the evaporator and smaller in the adiabatic and condenser. Three different liquids including water, methanol, and ethanol are separately filled within the heat pipe. Low heat fluxes are applied (up to 2500 W/m^2) in the evaporator and constant temperature water bath is used at three levels including 15, 25, and 35°C in the condenser. Results demonstrate that higher heat transfer coefficients are obtained for water and ethanol in comparison with methanol. Furthermore, increasing heat flux increases the evaporator heat transfer coefficient. For the case of methanol, some degradation in heat transfer coefficient is occurred at high heat fluxes which can be due to the surface dryout effect. Increasing the inclination angle decreases the heat pipe thermal resistance.
  • Keywords
    Heat pipe , Thermal resistance , Heat transfer coefficient , Methanol , Ethanol , Water
  • Journal title
    Ain Shams Engineering Journal
  • Journal title
    Ain Shams Engineering Journal
  • Record number

    2648892