Title of article :
Evaluation of Different Glazing Materials, Strategies, and Configurations in Flat Plate Collectors Using Glass and Acrylic Covers: An Experimental Assessment
Author/Authors :
Ameri, M Department of Mechanical Engineering - Shahid Bahonar University of Kerman - Kerman, Iran , Farzan, H Department of Mechanical Engineering - Higher Education Complex of Bam - Bam, Iran , Nobari, M Department of Mechanical Engineering - Shahid Bahonar University of Kerman - Kerman, Iran
Abstract :
Glass plates have been commonly used as collectors’ covers due to technical feasibility, high
transmissivity in shortwave solar irradiation, and low transmissivity in long-wavelengths.
However, they are vulnerable to stones and hail. Plastic plates have high transmissivity in
shortwaves but also have transmission bands in the middle of the thermal radiation spectrum.
The current study represents an experimental assessment of different covering strategies,
including single acrylic-cover, single glass-cover, double glass- acrylic cover, and double glasscover.
Two solar air heaters (SAHs) prototypes were constructed for this study. The acquired
experimental runs illustrated that the single glass-covered SAH represents higher thermal
performance than the single acrylic-covered SAH due to the lower transmissivity of glass plates
in long wavelengths. The double-covered SAHs have higher performance than the similar singlecovered
SAHs. In the double-covered SAHs, the convective-radiant heat loss is reduced. However,
increasing the cover number improves the radiant resistance to solar irradiation and reduces the
collector performance when solar irradiation is insufficient and the absorber temperature is low,
especially at the beginning of daytime hours. The SAH using a double-glass cover is preferable;
however, the heat dynamics of the double glass- acrylic-covered SAH are so close to the double
glass-covered one, and the acrylic plate is more resistant to harsh ambient conditions.
Farsi abstract :
ﺷﯿﺸﻪ ﺑﻪ دﻟﯿﻞ ﺳﻬﻮﻟﺖ ﮐﺎرﺑﺮي، ﺿﺮﯾﺐ ﻋﺒﻮر ﺑﺎﻻ در ﻃﻮل ﻣﻮجﻫﺎي ﮐﻮﺗﺎه و ﺿﺮﯾﺐ ﻋﺒﻮر ﭘﺎﯾﯿﻦ در ﻃﻮل ﻣﻮجﻫﺎي ﺑﻠﻨﺪ ﺑﻪ ﺷﮑﻞ ﻣﺘﺪاول ﺑﻪ ﻋﻨﻮان ﭘﻮﺷﺶ ﮔﺮﻣﮑﻦﻫﺎي ﺧﻮرﺷﯿﺪي ﻣﻮرد اﺳﺘﻔﺎده ﻗﺮار ﮔﺮﻓﺘﻪ اﺳﺖ. اﮔﺮﭼﻪ ﺷﯿﺸﻪﻫﺎ ﻧﺴﺒﺖ ﺑﻪ ﻋﻮاﻣﻞ ﺧﺎرﺟﯽ ﻣﺎﻧﻨﺪ ﺳﻨﮓ و ﺗﮕﺮگ آﺳﯿﺐ ﭘﺬﯾﺮ ﻫﺴﺘﻨﺪ. ﺻﻔﺤﻪﻫﺎي ﭘﻼﺳﺘﯿﮑﯽ داراي ﺿﺮﯾﺐ ﻋﺒﻮر ﺑﺎﻻ در ﻃﻮل ﻣﻮجﻫﺎي ﮐﻮﺗﺎه و ﻃﻮل ﻣﻮجﻫﺎي ﻣﯿﺎﻧﯽ ﻃﯿﻒ اﻧﺮژي ﮔﺮﻣﺎﯾﯽ ﺧﻮرﺷﯿﺪي ﻫﺴﺘﻨﺪ. در اﯾﻦ ﻣﻄﺎﻟﻌﻪ ﯾﮏ روش ﺗﺠﺮﺑﯽ ﺑﺮاي ارزﯾﺎﺑﯽ روﯾﮑﺮدﻫﺎي ﻣﺨﺘﻠﻒ ﭘﻮﺷﺸﯽ ﮔﺮﻣﮑﻦﻫﺎي ﺧﻮرﺷﯿﺪي ﺷﺎﻣﻞ ﭘﻮﺷﺶ ﺗﮏ اﮐﺮﯾﻠﯿﮏ، ﭘﻮﺷﺶ ﺗﮏ ﺷﯿﺸﻪ، ﭘﻮﺷﺶ دوﮔﺎﻧﻪ ﺷﯿﺸﻪ-اﮐﺮﯾﻠﯿﮏ و ﭘﻮﺷﺶ دوﮔﺎﻧﻪ ﺷﯿﺸﻪ ﺑﺮرﺳﯽ ﺷﺪه اﺳﺖ. ﺑﺮاي اﯾﻦ ﻣﻨﻈﻮر دو ﮔﺮﻣﮑﻦ ﺧﻮرﺷﯿﺪي ﻫﻮاﯾﯽ ﺳﺎﺧﺘﻪ ﺷﺪه اﺳﺖ. آزﻣﺎﯾﺶﻫﺎي ﺗﺠﺮﺑﯽ ﻧﺸﺎن ﻣﯽدﻫﻨﺪ ﮔﺮﻣﮕﻦ ﺑﺎ ﭘﻮﺷﺶ ﺗﮏ ﺷﯿﺸﻪ ﺑﻪ ﻋﻠﺖ ﺿﺮﯾﺐ ﻋﺒﻮر ﮐﻤﺘﺮ ﺷﯿﺸﻪ در ﻃﻮل ﻣﻮجﻫﺎي ﺑﻠﻨﺪ ﺑﺎزﺗﺎﺑﺸﯽ از ﺻﻔﺤﻪ ﺟﺎذب، راﻧﺪﻣﺎن ﺣﺮارﺗﯽ ﺑﺎﻻﺗﺮي ﻧﺴﺒﺖ ﺑﻪ ﮔﺮﻣﮑﻦ ﺑﺎ ﭘﻮﺷﺶ ﺗﮏ اﮐﺮﯾﻠﯿﮏ دارد. ﮔﺮﻣﮑﻦﻫﺎي ﺑﺎ ﭘﻮﺷﺶ دوﮔﺎﻧﻪ ﺑﻪ دﻟﯿﻞ ﮐﺎﻫﺶ اﺗﻼف ﺣﺮارﺗﯽ ﺟﺎﺑﺠﺎﯾﯽ-ﺗﺎﺑﺸﯽ داراي راﻧﺪﻣﺎن ﺑﺎﻻﺗﺮي ﻧﺴﺒﺖ ﮔﺮﻣﮑﻦﻫﺎي ﺑﺎ ﭘﻮﺷﺶ ﺗﮏ ﮔﺎﻧﻪ ﻫﺴﺘﻨﺪ. اﮔﺮﭼﻪ اﻓﺰاﯾﺶ ﺗﻌﺪاد ﻻﯾﻪﻫﺎي ﭘﻮﺷﺸﯽ، ﻣﻘﺎوﻣﺖ ﺗﺎﺑﺸﯽ در ﻣﻘﺎﺑﻞ اﻧﺮژي ﺧﻮرﺷﯿﺪي را اﻓﺰاﯾﺶ ﻣﯽدﻫﺪ و راﻧﺪﻣﺎن ﺣﺮارﺗﯽ ﮔﺮﻣﮑﻦ را ﺑﻪ وﯾﮋه در زﻣﺎنﻫﺎي اﺑﺘﺪاﯾﯽ ﺻﺒﺢ ﮐﻪ ﻣﻘﺪار ﺗﺎﺑﺶ و دﻣﺎي ﺻﻔﺤﻪ ﺟﺎذب ﮐﻢ اﺳﺖ، ﮐﺎﻫﺶ ﻣﯽدﻫﺪ. ﻧﺘﺎﯾﺞ ﺑﺪﺳﺖ آﻣﺪه ﻧﺸﺎن ﻣﯽدﻫﻨﺪ ﮔﺮﻣﮑﻦﻫﺎﯾﯽ ﺑﺎ ﭘﻮﺷﺶ دوﮔﺎﻧﻪ ﺷﯿﺸﻪ ﻣﻄﻠﻮﺑﺘﺮﯾﻦ ﺣﺎﻟﺖ ﭘﻮﺷﺶ اﺳﺖ، اﮔﺮﭼﻪ ﭘﺎﺳﺦ ﺣﺮارﺗﯽ ﮔﺮﻣﮑﻦ دوﮔﺎﻧﻪ ﺷﯿﺸﻪ-اﮐﺮﯾﻠﯿﮏ ﺑﺴﯿﺎر ﻧﺰدﯾﮏ ﺑﻪ ﭘﻮﺷﺶ دوﮔﺎﻧﻪ ﺷﯿﺸﻪ اﺳﺖ، اﮔﺮﭼﻪ ﭘﻮﺷﺶ اﮐﺮﯾﻠﯿﮏ ﻧﺴﺒﺖ ﺑﻪ ﺷﯿﺸﻪ در ﻣﻘﺎﺑﻞ ﺷﺮاﯾﻂ ﻣﺤﯿﻄﯽ ﺳﺨﺖ ﺑﺴﯿﺎر ﻣﻘﺎوﻣﺘﺮ اﺳﺖ.
Keywords :
Thermal performance , Covering configurations , Covering strategy , Experimental study , Heat dynamics , Solar air heater
Journal title :