Title of article :
Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations
Author/Authors :
Mishra, Pankaj Kumar Department of Orthopedics - Gandhi Medical College and Hamidia Hospital Bhopal M.P., India , Dwivedi, Rishi Department of Spine Center - MIOT International Chennai, India , Dhillon, Charanjit Singh Department of Spine Center - MIOT International Chennai, India
Abstract :
Objective: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods.
Methods: Totally, 81 patients were presented to our center with osteoporotic vertebral compression fracture. Among these, 59 patients (61 vertebrae) were enrolled with stable wedge osteoporotic compression fracture. Pre-operatively percentage of vertebral height loss and kyphotic angle were calculated and single balloon extrapedicular kyphoplasty was performed in all cases.
Results: Postoperatively, anterior vertebral height improved to 79.61% of normal subjects. In our study, the mean segmental kyphosis correction following balloon kyphoplasty was 14.27°. Overall incidence of cement leak in our study was 15.25%.
Conclusion: Although we encountered the few difficulties, but this technique holds the safety and feasibility measures. Furthermore, it is effective in restoring anterior vertebral height, alignment and angle of kyphosis.
Keywords :
Uni-extrapedicular , Balloon kyphoplasty , Percutaneous , Compression fracture
Journal title :
Bulletin of Emergency and Trauma