• Title of article

    Comparison between Cefoxitin disk diffusion, Crome agar and EPI-M Screening Kit for Detection of Methicillin- Resistant Staphylococcus aureus

  • Author/Authors

    Alwash, Samarah J. University of Baghdad - College of Science - Department of Biology, Iraq , Saleh, Dhuha S. University of Baghdad - College of Science - Department of Biology, Iraq

  • From page
    847
  • To page
    850
  • Abstract
    Specimens have been collected from one hundred and seventeen patients residing in local hospitals, 33 with burns and 84 wound injuries,. Three different methods ,Cefoxitin disk diffusion, EPI-M Screening Kit and Crome agar (MeReSa agar)with selective supplement were used to detect methicillin-resistant Staphylococcus aureus (MRSA) . A comparison was made between these 3 methods according to the results. It was found that the results of the Cefoxitin disk diffusion test were compatible with the results of culturing on Crome agar, while those obtained from the EPI-M Screening kit were not accurate and some of them gave false negative results.
  • Keywords
    MRSA , Burns , wounds , EPI , M , Cefoxitin , MeReSa agar
  • Journal title
    Iraqi Journal Of Science
  • Journal title
    Iraqi Journal Of Science
  • Record number

    2682807