Title of article :
Effect of Steps Height and Glass Cover Angle on Heat Transfer Performance for Solar Distillation: Numerical Study
Author/Authors :
Assari, M.R Department of Mechanical Engineering - Jundi-Shapur University of Technology - Dezful, Iran , Mirzavand, R Department of Mechanical Engineering - Jundi-Shapur University of Technology - Dezful, Iran , Basirat Tabrizi, H Department of Mechanical Engineering - Amirkabir University of Technology - Tehran, Iran , Gholi Beik, A Jafar
Abstract :
Productivity and heat transfer in the stepped solar still by varying the glass cover angle and steps height were numerically investigated. In order to obtain the productivity and heat transfer coefficient, mass, momentum, energy, and diffusion equations were applied for simulating the distillation process. Further, the numerical simulation validated by existed experimental data. Simulation results indicated the highest freshwater production in comparison with experimental set up condition, which is at the step height 4cm and glass cover angle 60.23◦, belongs to the step height of 5.5cm with 1400 mL/m2h, namely 91⁒ increase and much less for the step height of 1cm with 350 mL/m2h, namely 52⁒ decrease. Most increase in Nusselt number obtained for the angle of 55◦ with Nu=12.03 with 29⁒ increase and much less for the angle of 65◦ with Nu=8.16 with 12⁒ decrease. In addition, most and less variation of the heat transfer coefficient obtained for the step height of 5.5cm with hc=4.04 W/m2 K, with 39⁒ increase and for the step height of 1cm with hc=2.18 W/m2 K, with 24⁒ decrease, respectively
Farsi abstract :
ﭼﮑﯿﺪه در اﯾﻦ ﻣﻘﺎﻟﻪ، ﻣﻄﺎﻟﻌﻪاي ﻋﺪدي در ﺣﻮزهي ﺑﻬﺮه وري و اﻧﺘﻘﺎل ﺣﺮارت در آب ﺷﯿﺮﯾﻦ ﮐﻦ ﺧﻮرﺷﯿﺪي ﭘﻠﮑﺎﻧﯽ ﺑﺎ ﺗﻐﯿﯿﺮ زاوﯾﻪ ﭘﻮﺷﺶ ﺷﯿﺸﻪ و ارﺗﻔﺎع ﭘﻠﻪﻫﺎ ﻣﻮرد ﺑﺮرﺳﯽ ﻗﺮار ﮔﺮﻓﺘﻪ اﺳﺖ. ﺑﺪﯾﻦ ﻣﻨﻈﻮر از ﻣﻌﺎدﻻت ﭘﺎﯾﺴﺘﮕﯽ ﺟﺮم، ﺣﺮﮐﺖ، اﻧﺮژي و اﻧﺘﺸﺎر اﺳﺘﻔﺎده ﺷﺪ. ﻋﻼوه ﺑﺮ اﯾﻦ، ﺷﺒﯿﻪ ﺳﺎزي ﻋﺪدي ﺑﺎ داده ﻫﺎي ﺗﺠﺮﺑﯽ ﻣﻮﺟﻮد ﺗﺎﯾﯿﺪ ﺷﺪه اﺳﺖ. ﻧﺘﺎﯾﺞ ﺷﺒﯿﻪ ﺳﺎزي ﻧﺸﺎن داد ﮐﻪ ﺑﯿﺸﺘﺮﯾﻦ ﻣﯿﺰان ﺗﻮﻟﯿﺪ آب ﺷﯿﺮ ﯾﻦ در ﻣﻘﺎ ﯾﺴﻪ ﺑﺎ ﺷﺮاﯾ ﻂ راه اﻧﺪازي آزﻣﺎﯾﺸﯽ ﮐﻪ در ارﺗﻔﺎع ﭘﻠﻪ 4 ﺳﺎﻧﺘﯽ ﻣﺘﺮ و زاوﯾﻪ ﭘﻮﺷﺶ ﺷﯿﺸﻪ اي 60.23 درﺟﻪ اﺳﺖ، ﻣﺘﻌﻠﻖ ﺑﻪ ارﺗﻔﺎع ﭘﻠﻪ 5.5 ﺳﺎﻧﺘﯽ ﻣﺘﺮ ﺑﺎ mL/m2 h 1400 ﯾﻌﻨﯽ اﻓﺰاﯾﺶ 91 درﺟﻪ و ﺑﺴﯿﺎر ﮐﻤﺘﺮ اﺳﺖ. ﺑﺮاي ارﺗﻔﺎع ﭘﻠﻪ 1 ﺳﺎﻧﺘﯽ ﻣﺘﺮ ﺑﺎ 350 ﻣﯿﻠ ﯽ ﻟﯿﺘﺮﺑﺮﻣﺘﺮﻣﺮﺑﻊ ﺳﺎﻋﺖ، ﯾﻌﻨﯽ 52 درﺟﻪ ﮐﺎﻫﺶ ﻣﯽ ﯾﺎﺑﺪ. ﺑﯿﺸﺘﺮﯾﻦ اﻓﺰاﯾﺶ ﻋﺪد ﻧﺎﺳﻠﺖ ﺑﺮاي زاوﯾﻪ 55 درﺟﻪ ﺑﺎ 12.03=Nu ﺑﺎ اﻓﺰا ﯾﺶ 29 و ﺑﺴﯿﺎر ﮐﻤﺘﺮ ﺑﺮاي زاوﯾﻪ 65 درﺟﻪ ﺑﺎ 8.16=Nu ﺑﺎ ﮐﺎﻫﺶ 12 ﺑﺪﺳﺖ آمد...
Keywords :
Glass Cover Angle , Stepped Solar Still , Heat Transfer Performance , Solar Distillation , Numerical Analysis
Journal title :
International Journal of Engineering