Author/Authors :
Parvizi, Mahdieh Department of Radiopharmacy - Faculty of Pharmacy, -Tehran University of Medical Sciences, Tehran, Iran , Farzanefar, Saeed Department of Nuclear Medicine - Vali-Asr Hospital - Tehran University of Medical Sciences, Tehran, Iran , Tafakhori, Abbas Department of Neurology - School of Medicine - Imam Khomeini Hospital - Tehran University of Medical Sciences, Tehran, Iran , Gholami, Mahdi Department of Toxicology and Pharmacology - Faculty of Pharmacy - Tehran University of Medical Sciences, Tehran, Iran , Johari Dahae, Fariba Radiation Application Research School - Nuclear Science and Technology Research Institute, NSTRI, Tehran, Iran , Saffar, Hana Department of Pathology - Cancer Institute, Imam Khomeini Hospital - Tehran University of Medical Sciences, Tehran, Iran , Khalajg, Ali Department of Medicinal Chemistry - Faculty of Pharmacy - Tehran University of Medical Sciences, Tehran, Iran. , Abbasi, Mehrshad Department of Nuclear Medicine - Vali-Asr Hospital - Tehran University of Medical Sciences, Tehran, Iran
Abstract :
99mTc-HMPAO labeled platelet (LP) imaging may integrate thrombosis imaging into routine
clinical procedures. In the current study, we assessed the feasibility of the use of 99mTc-HMPAO
LP for imaging of small clots in an animal model. Thrombosis was induced by application of
FeCl3 solution in the distal part of the inferior vena cava (IVC) of a 6100 g anesthetized rabbit
and in a male Wistar rat weighing 420 g. Twenty minutes later, 178 MBq 99mTc-HMPAO LP was
injected. 99mTc-HMPAO LP preparation was done as defined and standardized in a previous report.
Whole body and SPECT imaging were done 60, 90, and 120 min after tracer injection. Then,
the clotted part of the vein was extracted and then its activity and pathologic evaluations were
compared with the proximal part of the IVC at a similar volume. A 17 × 6 mm clot was clearly
detected with both planar and SPECT imaging. The count to pixel ratio (CPR) of the clotted part
of the vein was 35, 40, and 40 compared to the non-clotted vein (i.e. 19, 18, and 21) at 60, 90, and
120 min, respectively. After clot extraction, the CPR decreased to 14. The clot activity was 0.44
MBq compared to 0.01 MBq of the normal control vein. Also, clot induction was pathologically
proven. 99mTc-HMPAO LP preparation is logistically possible in clinical nuclear medicine and the
ability of imaging small size clots encourages future trials for real clinical thrombotic scenarios.
Keywords :
99mTc-HMPAO , Labeled platelet , Thrombosis , Animal model , Scintigraphy