Title of article :
Investigation of under-containment gamma dose after total core uncovering accident in Tehran Research Reactor
Author/Authors :
Boustan, Ehsan Reactor and Nuclear Safety School - Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran , Hassanzadeh, Mostafa Reactor and Nuclear Safety School - Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran , Ahangari, Rohollah Reactor and Nuclear Safety School - Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran
Abstract :
The occurrence of core uncovering following a loss of coolant accident is conceivable and
should be taken into account for its significant possible consequences. Source terms are
calculated using ORIGEN 2.1 code, and the gamma dose of the uncovered core is calculated
for three different normal and anticipated accidents scenarios. Under containment
gamma dose rates have been calculated analytically as well as using MCNPX 2.6.0 code.
The uncovered core of the Tehran research reactor is supposed to operate in nominated
power of 5 MW for 30 days. The results illustrated that the under-containment dose rate
of gamma in some locations would be about 200 Sv.h−1, far from the annual occupational
exposure limit of 50 mSv. For preventing this occurrence, it would be possible to use an
emergency make-up tank as an engineered safety feature, with functions of the avoidance
of damaging fuel after the loss of coolant accident as well as controlling exposure from
the core.
Farsi abstract :
فاقد چكيده فارسي
Keywords :
Research Reactor , Total core uncovering , Gamma dose , Emergency make-up tank
Journal title :
Radiation Physics and Engineering