Title of article :
A Simplified Approach to Evaluate Retinal Blue Light Hazard Using the Correlated Color Temperature of LED Light Sources
Author/Authors :
Mohammadian ، Farough Department of Occupational Health and Safety Engineering - Environmental Health Research Center, Research Institute for Health Development - Kurdistan University of Medical Sciences , Mehri ، Ahmad Department of occupational hygiene - school of public health - Hamadan University of medical sciences , Abedi ، Kamaladdin Department of Occupational Health and Safety Engineering - Environmental Health Research Center, Research Institute for Health Development - Kurdistan University of Medical Sciences , Ebrahimi ، Hossein Department of Occupational Health and Safety Engineering - Iran University of Medical Sciences , Laal ، Fereydoon Department of Occupational Health - School of Health, Social Determinants of Health Research Center - Birjand University of Medical Sciences , Falahi ، Hamed Department of Safety Engineering - Faculty of Industry - Islamic Azad University, Qazvin Branch
Abstract :
Background: Visible light of short wavelength (blue light) can damage the retina cells, called blue light hazard. To protect the retina, permissible exposure limits have been determined by ICNIRP (the International Commission on Non-Ionizing Radiation Protection) and other health and safety agencies. These limits include complex physical concepts, and their evaluation requires light measuring instruments equipped with a blue light hazard function filter, which is not available at the moment in developing countries. This study aims to assess retinal blue light hazard using the correlated color temperature of Light-Emitting Diode (LED) light sources. Methods: In this study, a new method was proposed for evaluating the retinal blue light hazard using only the Correlated Color Temperature (CCL) of LED light sources for which concern on blue light hazard has currently been reinforced. In the proposed method, the radiometric quantity (blue light effective radiance) in W.m-2.sr-1 was converted to the corresponding photometric quantity (blue light effective luminance) in lm.m^-2.sr^-1. Then a computer code was developed for relevant calculations. Results: The estimated permissible exposure times applying the new photometry approach were highly reliable and supported by the literature. The proposed method is particularly useful because it eliminates the need to utilize any light measuring device. Conclusion: The new approach makes the concept of blue light hazard straightforward and understandable for all specialists dealing with optical radiation safety.
Keywords :
Blue light hazard , Permissible exposure time , Light , Emitting Diode (LED) , Correlated color temperature
Journal title :
Journal of Advances in Environmental Health Research
Journal title :
Journal of Advances in Environmental Health Research